Pepperl+Fuchs WHA-GW-F2D2-0-AS-Z2-ETH
WirelessHART Gateway
- MODBUS WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART and MODBUS protocol via both interfaces
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
Item Number:
WHA-GW-F2D2-0-AS-Z2-ETH
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Shock resistanceEN 60068-2-27
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Degree of protection | IEC 60529 |
Control elements | 2 push buttons: - restore HART configuration - restore communication configuration DIP switches: - baud rate - RS-485 address - RS-485 termination - security mode |
Interface 2 | RS-485 |
Power consumption | < 5 W |
Degree of protection | IP66/IP67 |
IECEx approval | IECEx FMG 12.0002 |
Interface | omnidirectional dipole antenna, removable |
Display elements | LED PWR (power supply status), one green LED LED COM (communication status), three yellow LEDs LED FLT (fault signal), one red LED |
Connection | screw terminals for - 0.2 ... 4 mm2 (rigid wire) - 0.2 ... 2.5 mm2 (flexible wire) |
Interface 1 | Ethernet 10 BASE-T/100 BASE-TX , full galvanic isolation |
Communication | WirelessHART specifications - physical layer: IEEE 802.15.4.2006 - frequency band: 2.4 GHz (ISM band, licence free) - transmission rate: 250 kBit/s - maximum transmit power: +10 dBm (EIRP) - transmission range: outdoor 250 m, indoor 50 m (under reference conditions) - communication standard: WirelessHART acc. to IEC 62591 |
Relative humidity | 5 ... 95 %, noncondensing |
Vibration resistance | EN 60068-2-6 |
EU-Type Examination Certificate | FM 12 ATEX 0061 |
Rated voltage | 20 ... 30 V DC SELV/PELV |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 |
Interface/interface | basic insulation according to IEC 61140, rated insulation voltage 50 Veff |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
FM approval | Coc3042646 |
Mounting | wall mounting |
Mass | approx. 1 kg |
Dimensions | 258 mm x 114 mm x 84 mm without antenna and cable glands |
Interface/power supply | basic insulation according to IEC 61140, rated insulation voltage 50 Veff |