Schneider Electric ATS48C17Q
Soft starter for asynchronous motor
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 45 kW at 230 V (connection in the motor supply line) for standard applications 37 kW at 230 V (connection in the motor supply line) for severe applications 132 kW at 400 V (connection to the motor delta terminals) for standard applications 110 kW at 400 V (connection to the motor delta terminals) for severe applications 90 kW at 400 V (connection in the motor supply line) for standard applications 90 kW at 230 V (connection to the motor delta terminals) for standard applications 75 kW at 400 V (connection in the motor supply line) for severe applications 75 kW at 230 V (connection to the motor delta terminals) for severe applications |
Item Number:
ATS48C17Q
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Product destination | Asynchronous motors |
Product specific application | Pumping and ventilation machine Severe and standard applications |
Component name | ATS48 |
Power supply voltage | 230...415 V (- 15...10 %) |
Motor power kW | 45 kW at 230 V (connection in the motor supply line) for standard applications 37 kW at 230 V (connection in the motor supply line) for severe applications 132 kW at 400 V (connection to the motor delta terminals) for standard applications 110 kW at 400 V (connection to the motor delta terminals) for severe applications 90 kW at 400 V (connection in the motor supply line) for standard applications 90 kW at 230 V (connection to the motor delta terminals) for standard applications 75 kW at 400 V (connection in the motor supply line) for severe applications 75 kW at 230 V (connection to the motor delta terminals) for severe applications |
Power dissipation in W | 479 W for standard applications 391 W for severe applications |
Utilisation category | AC-53A |
Type of start | Start with torque control (current limited to 5 In) |
Icl nominal current | 294 A (connection to the motor delta terminals)for standard applications 242 A (connection to the motor delta terminals)for severe applications 170 A (connection in the motor supply line)for standard applications 140 A (connection in the motor supply line)for severe applications |
IP degree of protection | IP00 |
Assembly style | With heat sink |
Function available | External bypass (optional) |
Power supply voltage limits | 195...456 V |
Device Full Name | Schneider Electric ATS48C17Q |