Schneider Electric ATS48C17Q
Product destinationAsynchronous motors
Product specific applicationPumping and ventilation machine
Severe and standard applications
Component nameATS48
Power supply voltage230...415 V (- 15...10 %)
Motor power kW45 kW at 230 V (connection in the motor supply line) for standard applications
37 kW at 230 V (connection in the motor supply line) for severe applications
132 kW at 400 V (connection to the motor delta terminals) for standard applications
110 kW at 400 V (connection to the motor delta terminals) for severe applications
90 kW at 400 V (connection in the motor supply line) for standard applications
90 kW at 230 V (connection to the motor delta terminals) for standard applications
75 kW at 400 V (connection in the motor supply line) for severe applications
75 kW at 230 V (connection to the motor delta terminals) for severe applications
Item Number: ATS48C17Q
3762.86
-
+
Total price: 3762.86
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Product destinationAsynchronous motors
Product specific applicationPumping and ventilation machine
Severe and standard applications
Component nameATS48
Power supply voltage230...415 V (- 15...10 %)
Motor power kW45 kW at 230 V (connection in the motor supply line) for standard applications
37 kW at 230 V (connection in the motor supply line) for severe applications
132 kW at 400 V (connection to the motor delta terminals) for standard applications
110 kW at 400 V (connection to the motor delta terminals) for severe applications
90 kW at 400 V (connection in the motor supply line) for standard applications
90 kW at 230 V (connection to the motor delta terminals) for standard applications
75 kW at 400 V (connection in the motor supply line) for severe applications
75 kW at 230 V (connection to the motor delta terminals) for severe applications
Power dissipation in W479 W for standard applications
391 W for severe applications
Utilisation categoryAC-53A
Type of startStart with torque control (current limited to 5 In)
Icl nominal current294 A (connection to the motor delta terminals)for standard applications
242 A (connection to the motor delta terminals)for severe applications
170 A (connection in the motor supply line)for standard applications
140 A (connection in the motor supply line)for severe applications
IP degree of protectionIP00
Assembly styleWith heat sink
Function availableExternal bypass (optional)
Power supply voltage limits195...456 V
Device Full NameSchneider Electric ATS48C17Q

Comments

No comments yet