Schneider Electric VW3A5505
Altivar Accessories
Value of inductance | 183.2 µH |
Product compatibility | Variable speed drive ATV930 wall mount, motor: 55...75 kW, 200...240 V Variable speed drive ATV630 wall mount, motor: 55...75 kW, 200...240 V Variable speed drive ATV950 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV930 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV650 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV630 wall mount, motor: 110...160 kW, 380...480 V |
Motor cable length | <= 500 m (shielded cable) motor: 55 kW 200...240 V, with 1 filter + VW3A5506 <= 500 m (unshielded cable) motor: 55...75 kW 200...240 V, with 2 filter <= 300 m (shielded cable) motor: 75 kW 200...240 V, with 2 filter <= 150 m (shielded cable) motor: 55 kW 200...240 V, with 1 filter <= 150 m (unshielded cable) motor: 55...75 kW 200...240 V, with 1 filter <= 500 m (shielded cable) motor: 110 kW 380...480 V, with 1 filter + VW3A5506 <= 500 m (unshielded cable) motor: 110...160 kW 380...480 V, with 2 filter <= 300 m (shielded cable) motor: 130...160 kW 380...480 V, with 2 filter <= 150 m (shielded cable) motor: 110 kW 380...480 V, with 1 filter <= 150 m (unshielded cable) motor: 110...160 kW 380...480 V, with 1 filter |
Saturation current | 3.6 A |
Internal diameter | 123.9 mm for PE cable outside 123.9 mm for 3-phase cable inside |
Item Number:
VW3A5505
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Value of inductance | 183.2 µH |
Product compatibility | Variable speed drive ATV930 wall mount, motor: 55...75 kW, 200...240 V Variable speed drive ATV630 wall mount, motor: 55...75 kW, 200...240 V Variable speed drive ATV950 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV930 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV650 wall mount, motor: 110...160 kW, 380...480 V Variable speed drive ATV630 wall mount, motor: 110...160 kW, 380...480 V |
Motor cable length | <= 500 m (shielded cable) motor: 55 kW 200...240 V, with 1 filter + VW3A5506 <= 500 m (unshielded cable) motor: 55...75 kW 200...240 V, with 2 filter <= 300 m (shielded cable) motor: 75 kW 200...240 V, with 2 filter <= 150 m (shielded cable) motor: 55 kW 200...240 V, with 1 filter <= 150 m (unshielded cable) motor: 55...75 kW 200...240 V, with 1 filter <= 500 m (shielded cable) motor: 110 kW 380...480 V, with 1 filter + VW3A5506 <= 500 m (unshielded cable) motor: 110...160 kW 380...480 V, with 2 filter <= 300 m (shielded cable) motor: 130...160 kW 380...480 V, with 2 filter <= 150 m (shielded cable) motor: 110 kW 380...480 V, with 1 filter <= 150 m (unshielded cable) motor: 110...160 kW 380...480 V, with 1 filter |
Saturation current | 3.6 A |
Internal diameter | 123.9 mm for PE cable outside 123.9 mm for 3-phase cable inside |
Electrical insulation class | Class I |
Mechanical robustness | Vibrations conforming to IEC 60721-3-3 class 3M4 Shocks conforming to IEC 60721-3-3 class 3M4 |
Switching frequency | <= 10 kHz |
Output frequency | 0...100 Hz |
Height | 197 mm |
Width | 191 mm |
Depth | 196 mm |
Product weight | 6 kg |
Device Full Name | Schneider Electric VW3A5505 |
People also buy
Comments
No comments yet