Sick AFM60A-S4AC262144
AFM60 Absolute encoder
We ship to United States of America!
- High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
- Face mount flange, servo flange, blind or through hollow shaft
- SSI, SSI + Incremental or SSI + Sin/Cos interface
Item Number:
AFM60A-S4AC262144
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Sick AFM60A-S4AC262144 is outdated.
Specification:
Part Number | 1037670 |
Connection type: | Male connector M12, 8-pin, radial |
Resolution: | 18 bit x 12 bit |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Maximum operating speed: | 9,000 /min |
Resolution power: | 262,144 x 4,096 |
Repeat accuracy: | 0.002 ° |
Reverse polarity protection: | 1 |
Operating voltage range: | 4.5 V DC ... 32 V DC |
Moment of inertia of the rotor: | 6.2 gcm? |
Code type: | Gray |
Storage temperature range: | -40 °C ... +100 °C, without package |
Clock frequency: | 2 MHz |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Permissible Load capacity of shaft: | 40 N (axial), 80 N (radial) |
Max. number of steps per revolution: | 262,144 |
Operating torque: | 0.3 Ncm (+20 °C) |
Working temperature range: | -30 °C ... +100 °C |
Initialization time: | 50 ms |
Resistance to vibration: | 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
Measuring step: | 0.014 ° 360 ° / number of steps |
Start up torque: | 0.5 Ncm (+20 °C) |
Electrical interface: | SSI/Gray |
Power consumption: | 0.5 W (without load) |
Interface signals: | Clock +, Clock -, Data +, Data- |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
Bearing lifetime: | 3.0 x 10^9 revolutions |
Error limits: | ± 0.03 ° |
Resistance to shocks: | 60 g, 6 ms (according to EN 60068-2-27) |
Measuring step deviation: | ± 0.002 ° |
Shaft diameter: | 10 mm |
Max. angular acceleration: | 500,000 rad/s? |
Max. number of revolutions: | 4,096 |
Code sequence: | CW/CCW, parameter adjustable |
MTTFd: mean time to dangerous failure: | 250 a (EN ISO 13849-1) |
CW/CCW (counting sequence when turning): | L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |
Mechanical interface: | Solid shaft with flat, Face mount flange |
SET (electronic adjustment): | H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |
Mass: | 0.26 kg |
Buy Sick AFM60A-S4AC262144 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is your reliable source for industrial electrical parts. Our extensive product range includes various automation equipment, all available for fast delivery. We guarantee quality and competitive prices. Make us your preferred partner for all your electrical supply needs.
People also buy
Comments
No comments yet