Sick AFM60B-S1AA004096
AFM60 Absolute encoder
We ship to United States of America!
- High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
- Face mount flange, servo flange, blind or through hollow shaft
- SSI, SSI + Incremental or SSI + Sin/Cos interface
Item Number:
AFM60B-S1AA004096
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1037868 |
Interface signals: | Clock +, Clock -, Data +, Data- |
Bearing lifetime: | 3.0 x 10^9 revolutions |
Power consumption: | 0.5 W (without load) |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Maximum operating speed: | 9,000 /min |
Shaft diameter: | 6 mm |
Error limits: | ± 0.05 ° |
MTTFd: mean time to dangerous failure: | 250 a (EN ISO 13849-1) |
Resistance to shocks: | 70 g (according to EN 60068-2-27) |
Electrical interface: | Connector M23, 12-pin, radial |
Resolution: | 12 bit x 12 bit |
Max. number of revolutions: | 4,096 |
Storage temperature range: | -40 °C ... 100 °C, without package |
Permissible Load capacity of shaft: | 40 N (axial), 80 N (radial) |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Resolution power: | 4,096 x 4,096 |
Measuring step deviation: | ± 0.01 ° |
Resistance to vibration: | 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
Measuring step: | 0.01 ° |
Operating voltage range: | 4.5 V DC ... 32 V DC |
Mechanical interface: | Solid shaft, Servo flange |
Mass: | 0.26 kg |
Max. number of steps per revolution: | 4,096 |
Initialization time: | 50 ms |
Clock frequency: | 2 MHz |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
Moment of inertia of the rotor: | 6.2 gcm? |
Max. angular acceleration: | 500,000 rad/s? |
Repeat accuracy: | 0.002 ° |
Operating torque: | 0.3 Ncm (20 °C) |
Working temperature range: | -30 °C ... 100 °C |
SET (electronic adjustment): | H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |
Start up torque: | 0.5 Ncm (20 °C) |
CW/CCW (counting sequence when turning): | L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) |