Sick AFS60B-S4AC008192
AFS60 Absolute encoder

Sick AFS60B-S4AC008192
We ship to United States of America!
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
Item Number: AFS60B-S4AC008192
481.80
-
+
Total price: 481.80
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick AFS60B-S4AC008192 is outdated.

Specification:

Part Number1037968
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Code type:Gray
Measuring step:0.01 °
Reverse polarity protection:1
Maximum operating speed:9,000 /min
Resistance to shocks:70 g, 6 ms (according to EN 60068-2-27)
Resolution power:8,192 x 1
Working temperature range:-30 °C ... 100 °C
Start up torque:0.5 Ncm (20 °C)
Storage temperature range:-40 °C ... 100 °C, without package
Mechanical interface:Solid shaft with flat, Face mount flange
Operating torque:0.3 Ncm (20 °C)
Initialization time:50 ms
Max. angular acceleration:500,000 rad/s²
Type of mounting shaft:Solid shaft with flat
Bearing lifetime:3.0 x 10^9 revolutions
Operating voltage range:4.5 V DC ... 32 V DC
Permissible Load capacity of shaft:40 N (axial), 80 N (radial)
Repeat accuracy:0.002 °
Interface signals:Clock +, Clock -, Data +, Data-
Moment of inertia of the rotor:6.2 gcm²
Error limits:± 0.05 °
Connection type:Male connector M12, 8-pin, radial
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Measuring step deviation:± 0.01 °
:Face mount flange
Max. number of steps per revolution:8,192
Shaft diameter:10 mm
Mass:0.26 kg
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Max. number of revolutions:1
Power consumption:0.5 W (without load)
Electrical interface:SSI/Gray
Clock frequency:2 MHz
Code sequence:CW/CCW, parameter adjustable

Buy Sick AFS60B-S4AC008192 with the best possible price and delivery terms on eltra-trade.com

Discover a wide variety of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment