Sick ARS60-J4A00360

ARS60-J
Sick ARS60-J4A00360
609.38
One click request

Specification:

Part Number1031727
Measuring step:360 ° /number of lines
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Permissible Load capacity of shaft:20 N (radial)
10 N (axial)
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Working temperature range:-20 °C ... 85 °C
Operating torque:0.3 Ncm
Max. number of revolutions:1
EMC:According to EN 61000-6-2 and EN 61000-6-3
Bearing lifetime:3.6 x 10^9 revolutions
Resolution power:360 x 1
Error limits:0.035 ° (binary number of steps)
0.046 ° (non-binary number of steps)
Measuring step deviation:0.005 °, 0.016 °
Initialization time:80 ms
Mechanical interface:Solid shaft, Face mount flange
Operating voltage range:10 V DC ... 32 V DC
Shaft diameter:10 mm
Maximum operating speed:10,000 /min (without shaft seal)
6,000 /min (with shaft seal)
Repeat accuracy:0.005 °
Enclosure rating:IP 65, according to IEC 60529, with mating connector fitted

Max. angular acceleration:500,000 rad/s²
Resistance to shocks:50 g (according to EN 60068-2-27)
Operation of zero-set:≥ 100 ms
Storage temperature range:-40 °C ... 100 °C
Mass:0.3 kg
Max. number of steps per revolution:360
Start up torque:0.4 Ncm
Moment of inertia of the rotor:54 gcm²
Electrical interface:Connector M23, 21-pin, radial
Operating power consumption (no load):90 mA