Sick BCG19-P1BM1015
Wire Draw (Rope) Encoders
- Measuring lengths of 1.25 m, 3 m, 5 m, and 10 m.
- Very small dimension (55 ... 190 mm)
- Modular system: encoder type, measuring length, and interface can be selected
Item Number:
BCG19-P1BM1015
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Specification:
Part Number | 1052620 |
Address setting: | 0 ... 127, DIP switch |
Life of wire draw mechanism: | 1 million cycles |
Wire acceleration: | 8 m/s² |
Mass (mechanics): | 1.9 kg |
Relative humidity / Condensation: | 95 % (condensation of the optical scanning not permitted) |
Operating speed: | 4 m/s |
Power consumption: | 1.5 W |
Measuring wire diameter: | 0.55 mm |
Part number mechanic: | 5326242 |
Resistance to vibration: | 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
Measuring range: | 0 m ... 10 m |
Part number encoder: | 1051018 |
MTTFd: mean time to dangerous failure: | 60 a |
Connection type: | Connector 3 x M12, 5-pin, axial |
Encoder profile: | Encoder profile version 1.1 class 1 and class 2 |
Enclosure rating mechanic: | IP 50 |
SET (electronic adjustment): | Via PRESET push button or protocol |
Mass (measuring wire): | 1.2 g/m |
Spring return force: | Ca. 9 N ... ca. 12 N |
Protocol: | PROFIBUS DP V0 |
Encoder: | Absolute encoders |
Supply voltage: | 10 V ... 32 V |
Resolution (wire draw + encoder): | 0.07 mm |
Measuring wire material: | Highly flexible stranded steel 1.4401 stainless steel V4A |
Hysteresis: | ≤ 0.4 mm |
Working temperature range (combination): | Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik |
Housing material, wire draw mechanism: | Plastic, Noryl |
Mounted encoder: | A3M60 |
Electrical interface: | PROFIBUS |
Resistance to shocks: | 80 g, 6 ms (according to EN 60068-2-27) |
Linearity: | ≤ ± 2 mm |
Working temperature range (mechanics): | -30 °C ... +70 °C |
Number of steps per revolution: | 8,192 |
Bus termination: | Via DIP switches |
Repeatability: | ≤ 0.2 mm |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Mass (including encoder): | 2.18 kg |
Mounted mechanic: | MRA-G190-110D3 |
Length of wire pulled out per revolution: | 555 mm |
Actual length of cable extension: | 10.2 m |
Working temperature range (encoder): | -10 °C ... +70 °C |
Initialization time: | Ca. 1 s |
Enclosure rating encoder: | IP 67 |
People also buy
Comments