Sick BTF08-A1AM0240
Absolute encoder

Sick BTF08-A1AM0240

Absolute encoder

Item Number: BTF08-A1AM0240
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The product has been Discontinued by the Manufacturer!

Contact sales manager for a replacement.

  • Absolute wire draw encoders

  • Modular measuring system with a wide selection of interfaces/measuring lengths

  • Measuring lengths: 2 m ... 50 m

Part Number1034299
SET (electronic adjustment):Via SET cable
Enclosure rating encoder:IP 67
MTTFd: mean time to dangerous failure:150 a
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Mounted mechanic:MRA-F080-102D2
Operating speed:4 m/s
Electrical interface:SSI
Power consumption:0.8 W
Spring return force:6 N ... 14 N
Supply voltage:10 V ... 32 V
Housing material, wire draw mechanism:Aluminum (anodised), die-cast zinc
Resistance to shocks:10 g, 6 ms (according to EN 60068-2-27)
Mass (including encoder):1.8 kg
Part number encoder:1034293
Working temperature range (combination):Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Code type:Gray
Life of wire draw mechanism:1 million cycles
Encoder:Absolute encoders
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Wire acceleration:40 m/s²
Linearity:≤ ± 2 mm
Connection type:Connector M23, 12-pin, radial
Number of steps per revolution:8,000
Length of wire pulled out per revolution:200 mm
Clock frequency:1 MHz
Hysteresis:≤ 2 mm
Mass (mechanics):1.3 kg
Mass (measuring wire):7.1 g/m
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Working temperature range (mechanics):-30 °C ... +70 °C
Part number mechanic:6028625
Measuring range:0 m ... 2 m
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Resolution (wire draw + encoder):0.025 mm
Repeatability:≤ 1 mm
Actual length of cable extension:2.2 m
Measuring wire diameter:1.35 mm
Mounted encoder:ATM60 SSI
Initialization time:Ca. 1,050 ms
Enclosure rating mechanic:IP 64
Working temperature range (encoder):-20 °C ... +70 °C

Comments

No comments yet