- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-01214BBC03BE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207793 |
External device monitoring (EDM): | + |
Cascaded: | - |
Restart interlock: | + |
Category: | Category 2 (EN ISO 13849) |
TM (mission time): | 20 a (EN ISO 13849) |
Typical range: | 0 m ... 8 m |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Protection class: | III (EN 61140) |
Connection type: | Male connector M12, 5-pin |
Ambient operating temperature: | -20 °C ... +55 °C |
External device monitoring (delivery status): | Deactivated |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Response time: | ≤ 14 ms |
Resolution: | 14 mm |
Switching voltage LOW: | 2 V DC |
Weight: | 50 g |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Conductor cross-section: | 0.34 mm? |
Ripple: | ≤ 10 % |
Restart interlock (delivery status): | Deactivated |
Cable length: | 160 mm |
Automatic beam coding: | + |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Scanning range: | 0 m ... 6 m |
Protective field height: | 120 mm |
Synchronization: | Optical, without separate synchronization |
Enclosure rating: | IP 65 (EN 60529) |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Power consumption: | ≤ 3 A |
Switching current: | 300 mA |
Type: | Type 2 (IEC 61496) |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Display elements: | LEDs |
Permitted cable length: | ≤ 20 m |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Configuration method: | Hard wired |
Beam coding: | + |
Safe SICK device communication via EFI/SDL: | - |
Test rate (internal test): | 58 /s |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
Storage temperature: | -25 °C ... +70 °C |
Air humidity: | 15 % ... 95 %, non-condensing |
Buy Sick C2MT-01214BBC03BE0 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. offers electrical products online. We offer a comprehensive range of reliable and high-efficiency products. Express delivery is available to all our clients. We offer only original products from well-known manufacturers. If you need the products very urgently, we will do our best to provide you with the fastest delivery. We have a lot of positive feedback from our clients and partners, we are recommended!