Sick C2MT-01214BBC03BE0
Light curtains

Sick C2MT-01214BBC03BE0
We ship to United States of America!
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-01214BBC03BE0
376.20
-
+
Total price: 376.20
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207793
External device monitoring (EDM):+
Cascaded:-
Restart interlock:+
Category:Category 2 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Typical range:0 m ... 8 m
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Protection class:III (EN 61140)
Connection type:Male connector M12, 5-pin
Ambient operating temperature:-20 °C ... +55 °C
External device monitoring (delivery status):Deactivated
Maximum demand rate:34 /min (EN ISO 13849)
Response time:≤ 14 ms
Resolution:14 mm
Switching voltage LOW:2 V DC
Weight:50 g
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Conductor cross-section:0.34 mm?
Ripple:≤ 10 %
Restart interlock (delivery status):Deactivated
Cable length:160 mm
Automatic beam coding:+
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Housing material:Aluminum alloy ALMGSI 0.5
Scanning range:0 m ... 6 m
Protective field height:120 mm
Synchronization:Optical, without separate synchronization
Enclosure rating:IP 65 (EN 60529)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Power consumption:≤ 3 A
Switching current:300 mA
Type:Type 2 (IEC 61496)
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Display elements:LEDs
Permitted cable length:≤ 20 m
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Configuration method:Hard wired
Beam coding:+
Safe SICK device communication via EFI/SDL:-
Test rate (internal test):58 /s
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Housing cross-section (incl. system connection):15 mm x 32 mm
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Storage temperature:-25 °C ... +70 °C
Air humidity:15 % ... 95 %, non-condensing

Buy Sick C2MT-01214BBC03BE0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers electrical products online. We offer a comprehensive range of reliable and high-efficiency products. Express delivery is available to all our clients. We offer only original products from well-known manufacturers. If you need the products very urgently, we will do our best to provide you with the fastest delivery. We have a lot of positive feedback from our clients and partners, we are recommended!

Comments

No comments yet

Write a comment