Sick C2MT-02414BBC03DE0
Light curtains

Sick C2MT-02414BBC03DE0
We ship to United States of America!
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-02414BBC03DE0
458.70
-
+
Total price: 458.70
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207795
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Display elements:LEDs
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Resolution:14 mm
Typical range:0 m ... 8 m
Housing material:Aluminum alloy ALMGSI 0.5
Housing cross-section (incl. system connection):15 mm x 32 mm
Ripple:≤ 10 %
Storage temperature:-25 °C ... +70 °C
External device monitoring (EDM):+
Weight:95 g
Shock resistance:10 g, 16 ms (EN 60068-2-27)
TM (mission time):20 a (EN ISO 13849)
Connection type:Male connector M12, 5-pin
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Cable length:350 mm
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Restart interlock (delivery status):Deactivated
Enclosure rating:IP 65 (EN 60529)
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Switching current:300 mA
Type:Type 2 (IEC 61496)
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Beam coding:+
Protective field height:240 mm
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
External device monitoring (delivery status):Deactivated
Power consumption:≤ 3 A
Protection class:III (EN 61140)
Configuration method:Hard wired
Automatic beam coding:+
Switching voltage LOW:2 V DC
Cascaded:-
Test rate (internal test):58 /s
Maximum demand rate:34 /min (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Response time:≤ 14 ms
Scanning range:0 m ... 6 m
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Synchronization:Optical, without separate synchronization
Air humidity:15 % ... 95 %, non-condensing
Conductor cross-section:0.34 mm?
Ambient operating temperature:-20 °C ... +55 °C
Permitted cable length:≤ 20 m
Restart interlock:+
Category:Category 2 (EN ISO 13849)

Buy Sick C2MT-02414BBC03DE0 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online store of industrial automation equipment. New items of automation products are added every day. Your order can be quickly delivered throughout Europe and around the world. We offer you good value for money. We provide our customers with a very quick response and good conditions. Using our professional services will help you be more competitive in the market and it will save you time.