Sick C2MT-02424BBC03DB0
Light curtains

Sick C2MT-02424BBC03DB0
We ship to United States of America!
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-02424BBC03DB0
418.00
-
+
Total price: 418.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207944
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Permitted cable length:≤ 20 m
Restart interlock:+
Protection class:III (EN 61140)
Scanning range:0 m ... 6 m
Storage temperature:-25 °C ... +70 °C
Weight:95 g
Maximum demand rate:34 /min (EN ISO 13849)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
External device monitoring (EDM):+
Housing cross-section (incl. system connection):15 mm x 32 mm
Test rate (internal test):58 /s
Beam coding:+
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Configuration method:Hard wired
Cascaded:-
Protective field height:240 mm
Switching voltage LOW:2 V DC
Automatic beam coding:+
TM (mission time):20 a (EN ISO 13849)
Enclosure rating:IP 65 (EN 60529)
Typical range:0 m ... 8 m
Cable length:350 mm
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Display elements:LEDs
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Ambient operating temperature:-20 °C ... +55 °C
Response time:≤ 13 ms
Switching current:300 mA
Resolution:24 mm
Restart interlock (delivery status):Deactivated
Synchronization:Optical, without separate synchronization
Air humidity:15 % ... 95 %, non-condensing
Connection type:Male connector M12, 5-pin
Type:Type 2 (IEC 61496)
Safe SICK device communication via EFI/SDL:-
External device monitoring (delivery status):Deactivated
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Conductor cross-section:0.34 mm?
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Power consumption:≤ 3 A
Category:Category 2 (EN ISO 13849)
Housing material:Aluminum alloy ALMGSI 0.5
Ripple:≤ 10 %

Buy Sick C2MT-02424BBC03DB0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.

Comments

No comments yet

Write a comment