Sick C2MT-03034BBC03DE0
Light curtains
We ship to United States of America!
- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-03034BBC03DE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207850 |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Switching current: | 300 mA |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Typical range: | 0 m ... 8 m |
Restart interlock: | + |
Synchronization: | Optical, without separate synchronization |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Connection type: | Male connector M12, 5-pin |
Test rate (internal test): | 58 /s |
Power consumption: | ≤ 3 A |
Cascaded: | - |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Air humidity: | 15 % ... 95 %, non-condensing |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Switching voltage LOW: | 2 V DC |
Permitted cable length: | ≤ 20 m |
Protective field height: | 300 mm |
Automatic beam coding: | + |
Beam coding: | + |
Protection class: | III (EN 61140) |
Weight: | 115 g |
Configuration method: | Hard wired |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
External device monitoring (EDM): | + |
Restart interlock (delivery status): | Deactivated |
Category: | Category 2 (EN ISO 13849) |
Ripple: | ≤ 10 % |
Cable length: | 350 mm |
Display elements: | LEDs |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
Ambient operating temperature: | -20 °C ... +55 °C |
Storage temperature: | -25 °C ... +70 °C |
Type: | Type 2 (IEC 61496) |
Safe SICK device communication via EFI/SDL: | - |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Conductor cross-section: | 0.34 mm? |
External device monitoring (delivery status): | Deactivated |
Enclosure rating: | IP 65 (EN 60529) |
Scanning range: | 0 m ... 6 m |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Resolution: | 34 mm |
Response time: | ≤ 13 ms |
TM (mission time): | 20 a (EN ISO 13849) |
Buy Sick C2MT-03034BBC03DE0 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an online store of industrial automation equipment. Wе offer you a lot of spare parts that you cannot purchase on the market. We provide super fast delivery to any country. Become our partner and get great discounts. It is easy to make an order and to get the best quote. Send us a request and we will exceed your expectations.
People also buy
Comments