Sick C2MT-03614BBC03DE0
Light curtains
We ship to United States of America!
- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-03614BBC03DE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207797 |
Air humidity: | 15 % ... 95 %, non-condensing |
Ambient operating temperature: | -20 °C ... +55 °C |
Configuration method: | Hard wired |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Connection type: | Male connector M12, 5-pin |
Permitted cable length: | ≤ 20 m |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Protection class: | III (EN 61140) |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Cable length: | 350 mm |
Resolution: | 14 mm |
Conductor cross-section: | 0.34 mm? |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Power consumption: | ≤ 3 A |
Category: | Category 2 (EN ISO 13849) |
Ripple: | ≤ 10 % |
Switching current: | 300 mA |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
TM (mission time): | 20 a (EN ISO 13849) |
Test rate (internal test): | 58 /s |
Scanning range: | 0 m ... 6 m |
Automatic beam coding: | + |
Typical range: | 0 m ... 8 m |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Type: | Type 2 (IEC 61496) |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Cascaded: | - |
Restart interlock (delivery status): | Deactivated |
Switching voltage LOW: | 2 V DC |
External device monitoring (EDM): | + |
Response time: | ≤ 14 ms |
Weight: | 135 g |
Restart interlock: | + |
Synchronization: | Optical, without separate synchronization |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Safe SICK device communication via EFI/SDL: | - |
Storage temperature: | -25 °C ... +70 °C |
Protective field height: | 360 mm |
External device monitoring (delivery status): | Deactivated |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Beam coding: | + |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
Display elements: | LEDs |
Enclosure rating: | IP 65 (EN 60529) |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Buy Sick C2MT-03614BBC03DE0 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. offers factory automation products. You can find a huge online catalog of automation equipment on our website. We provide super fast delivery to any country. Get the exclusive offer, contact us now! We strive to deliver your order on time, following our obligations. We are constantly developing to satisfy all your needs in electrical equipment supply.