Sick C2MT-04214BBC03DE0
Light curtains

Sick C2MT-04214BBC03DE0
We ship to United States of America!
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-04214BBC03DE0
576.40
-
+
Total price: 576.40
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207798
Maximum demand rate:34 /min (EN ISO 13849)
Permitted cable length:≤ 20 m
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Protection class:III (EN 61140)
Switching voltage LOW:2 V DC
Weight:155 g
Protective field height:420 mm
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Switching current:300 mA
Enclosure rating:IP 65 (EN 60529)
Resolution:14 mm
Synchronization:Optical, without separate synchronization
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Restart interlock (delivery status):Deactivated
Scanning range:0 m ... 6 m
Ripple:≤ 10 %
Beam coding:+
Safe SICK device communication via EFI/SDL:-
Housing cross-section (incl. system connection):15 mm x 32 mm
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Housing material:Aluminum alloy ALMGSI 0.5
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
TM (mission time):20 a (EN ISO 13849)
Typical range:0 m ... 8 m
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Ambient operating temperature:-20 °C ... +55 °C
Category:Category 2 (EN ISO 13849)
Power consumption:≤ 3 A
Type:Type 2 (IEC 61496)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Restart interlock:+
Shock resistance:10 g, 16 ms (EN 60068-2-27)
External device monitoring (delivery status):Deactivated
External device monitoring (EDM):+
Display elements:LEDs
Response time:≤ 14 ms
Configuration method:Hard wired
Test rate (internal test):58 /s
Automatic beam coding:+
Connection type:Male connector M12, 5-pin
Cascaded:-
Conductor cross-section:0.34 mm?
Air humidity:15 % ... 95 %, non-condensing
Storage temperature:-25 °C ... +70 °C
Cable length:350 mm
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)

Buy Sick C2MT-04214BBC03DE0 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online electrical parts store. We offer a huge industrial automation products list. We ship to every country with the shortest possible terms. Get the original products of many brands from Eltra Trade company with guaranteed quality. Our managers are always quick to answer customer queries. Thanks to us you will be able to get rid of the cooperation with many suppliers, which greatly accelerates and facilitates your work.

Comments

No comments yet

Write a comment