  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-06614BBC03FE0
737.00
-
+
Total price: 737.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207802
Category:Category 2 (EN ISO 13849)
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Protection class:III (EN 61140)
Cable length:700 mm
External device monitoring (EDM):+
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Conductor cross-section:0.34 mm?
Restart interlock (delivery status):Deactivated
Protective field height:660 mm
Ambient operating temperature:-20 °C ... +55 °C
Housing cross-section (incl. system connection):15 mm x 32 mm
TM (mission time):20 a (EN ISO 13849)
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Beam coding:+
Switching voltage LOW:2 V DC
Weight:235 g
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Connection type:Male connector M12, 5-pin
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Permitted cable length:≤ 20 m
Scanning range:0 m ... 6 m
Safe SICK device communication via EFI/SDL:-
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Restart interlock:+
Enclosure rating:IP 65 (EN 60529)
Display elements:LEDs
Typical range:0 m ... 8 m
Switching current:300 mA
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Power consumption:≤ 3 A
Ripple:≤ 10 %
Air humidity:15 % ... 95 %, non-condensing
Cascaded:-
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Resolution:14 mm
Type:Type 2 (IEC 61496)
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Housing material:Aluminum alloy ALMGSI 0.5
Synchronization:Optical, without separate synchronization
Test rate (internal test):58 /s
Response time:≤ 14 ms
Automatic beam coding:+
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Maximum demand rate:34 /min (EN ISO 13849)
Storage temperature:-25 °C ... +70 °C
External device monitoring (delivery status):Deactivated
Configuration method:Hard wired