  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-06614BBC03FE0
737.00
-
+
Total price: 737.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207802
Category:Category 2 (EN ISO 13849)
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Protection class:III (EN 61140)
Cable length:700 mm
External device monitoring (EDM):+
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Conductor cross-section:0.34 mm?
Restart interlock (delivery status):Deactivated
Protective field height:660 mm
Ambient operating temperature:-20 °C ... +55 °C
Housing cross-section (incl. system connection):15 mm x 32 mm
TM (mission time):20 a (EN ISO 13849)
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Beam coding:+
Switching voltage LOW:2 V DC
Weight:235 g
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Connection type:Male connector M12, 5-pin
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Permitted cable length:≤ 20 m
Scanning range:0 m ... 6 m
Safe SICK device communication via EFI/SDL:-
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Restart interlock:+
Enclosure rating:IP 65 (EN 60529)
Display elements:LEDs
Typical range:0 m ... 8 m
Switching current:300 mA
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Power consumption:≤ 3 A
Ripple:≤ 10 %
Air humidity:15 % ... 95 %, non-condensing
Cascaded:-
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Resolution:14 mm
Type:Type 2 (IEC 61496)
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Housing material:Aluminum alloy ALMGSI 0.5
Synchronization:Optical, without separate synchronization
Test rate (internal test):58 /s
Response time:≤ 14 ms
Automatic beam coding:+
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Maximum demand rate:34 /min (EN ISO 13849)
Storage temperature:-25 °C ... +70 °C
External device monitoring (delivery status):Deactivated
Configuration method:Hard wired

Buy Sick C2MT-06614BBC03FE0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers industrial control products. There are many spare parts in stock. For your convenience, we can organize express delivery. We will choose the products that will best meet your needs at the lowest price. Our managers are always quick to answer customer queries. We respect your needs and are interested in their total satisfaction.