- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-09614BBC03FE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207817 |
Type: | Type 2 (IEC 61496) |
Test rate (internal test): | 58 /s |
Permitted cable length: | ≤ 20 m |
Restart interlock (delivery status): | Deactivated |
External device monitoring (delivery status): | Deactivated |
Resolution: | 14 mm |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Beam coding: | + |
Display elements: | LEDs |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Protective field height: | 960 mm |
Weight: | 340 g |
Ambient operating temperature: | -20 °C ... +55 °C |
Configuration method: | Hard wired |
Automatic beam coding: | + |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Enclosure rating: | IP 65 (EN 60529) |
Response time: | ≤ 17 ms |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Cascaded: | - |
Storage temperature: | -25 °C ... +70 °C |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Connection type: | Male connector M12, 5-pin |
Power consumption: | ≤ 3 A |
Ripple: | ≤ 10 % |
Category: | Category 2 (EN ISO 13849) |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Switching voltage LOW: | 2 V DC |
Switching current: | 300 mA |
Synchronization: | Optical, without separate synchronization |
Protection class: | III (EN 61140) |
Scanning range: | 0 m ... 6 m |
Typical range: | 0 m ... 8 m |
External device monitoring (EDM): | + |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
Conductor cross-section: | 0.34 mm² |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Cable length: | 700 mm |
TM (mission time): | 20 a (EN ISO 13849) |
Air humidity: | 15 % ... 95 %, non-condensing |
Restart interlock: | + |
Safe SICK device communication via EFI/SDL: | - |