Sick C2MT-10214BBC03FE0
Light curtains

Sick C2MT-10214BBC03FE0
We ship to United States of America!
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C2MT-10214BBC03FE0
974.60
-
+
Total price: 974.60
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207818
Switching current:300 mA
Maximum demand rate:34 /min (EN ISO 13849)
Cable length:700 mm
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Resolution:14 mm
Category:Category 2 (EN ISO 13849)
Housing material:Aluminum alloy ALMGSI 0.5
Beam coding:+
Restart interlock:+
Type:Type 2 (IEC 61496)
Ambient operating temperature:-20 °C ... +55 °C
Synchronization:Optical, without separate synchronization
Configuration method:Hard wired
Weight:360 g
Cascaded:-
Restart interlock (delivery status):Deactivated
Typical range:0 m ... 8 m
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Connection type:Male connector M12, 5-pin
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Automatic beam coding:+
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Storage temperature:-25 °C ... +70 °C
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Permitted cable length:≤ 20 m
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Enclosure rating:IP 65 (EN 60529)
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Housing cross-section (incl. system connection):15 mm x 32 mm
Test rate (internal test):58 /s
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Protective field height:1,020 mm
Safe SICK device communication via EFI/SDL:-
Display elements:LEDs
Ripple:≤ 10 %
Conductor cross-section:0.34 mm²
Response time:≤ 17 ms
Scanning range:0 m ... 6 m
External device monitoring (delivery status):Deactivated
Switching voltage LOW:2 V DC
Protection class:III (EN 61140)
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Power consumption:≤ 3 A
Air humidity:15 % ... 95 %, non-condensing
External device monitoring (EDM):+
TM (mission time):20 a (EN ISO 13849)

Buy Sick C2MT-10214BBC03FE0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers factory automation products. We offer a comprehensive range of reliable and high-efficiency products. For your convenience, we can arrange express delivery worldwide. Guaranteed quality with the minimum possible prices. You will get your order fast and with good prices. We are focused on long-term cooperation and mutual benefit.

Comments

No comments yet

Write a comment