Sick C2MT-12024BBC03FE0
Light curtains
We ship to United States of America!
- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-12024BBC03FE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207846 |
Display elements: | LEDs |
Air humidity: | 15 % ... 95 %, non-condensing |
Protective field height: | 1,200 mm |
Conductor cross-section: | 0.34 mm² |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
External device monitoring (delivery status): | Deactivated |
Protection class: | III (EN 61140) |
External device monitoring (EDM): | + |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Ripple: | ≤ 10 % |
Enclosure rating: | IP 65 (EN 60529) |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
Weight: | 420 g |
Test rate (internal test): | 58 /s |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Automatic beam coding: | + |
Beam coding: | + |
Synchronization: | Optical, without separate synchronization |
Configuration method: | Hard wired |
Safe SICK device communication via EFI/SDL: | - |
Cascaded: | - |
Response time: | ≤ 13 ms |
Switching voltage LOW: | 2 V DC |
Connection type: | Male connector M12, 5-pin |
Power consumption: | ≤ 3 A |
Category: | Category 2 (EN ISO 13849) |
Restart interlock: | + |
Resolution: | 24 mm |
Ambient operating temperature: | -20 °C ... +55 °C |
Permitted cable length: | ≤ 20 m |
Type: | Type 2 (IEC 61496) |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Restart interlock (delivery status): | Deactivated |
TM (mission time): | 20 a (EN ISO 13849) |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Scanning range: | 0 m ... 6 m |
Storage temperature: | -25 °C ... +70 °C |
Typical range: | 0 m ... 8 m |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
Cable length: | 700 mm |
Switching current: | 300 mA |
Buy Sick C2MT-12024BBC03FE0 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com is an electrical online store. We offer a full range of industrial automation equipment. Your order can be shipped with super fast delivery! Discover the best price in our web catalog. The offer submission date is always optimal for you. Safety, simplicity, and support during every stage.
People also buy
Comments