Sick C2MT-12034BBC03FE0
Light curtains
We ship to United States of America!
- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C2MT-12034BBC03FE0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207865 |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
TM (mission time): | 20 a (EN ISO 13849) |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
Beam coding: | + |
Connection type: | Male connector M12, 5-pin |
Cable length: | 700 mm |
Category: | Category 2 (EN ISO 13849) |
Permitted cable length: | ≤ 20 m |
Scanning range: | 0 m ... 6 m |
Conductor cross-section: | 0.34 mm? |
Restart interlock (delivery status): | Deactivated |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Storage temperature: | -25 °C ... +70 °C |
External device monitoring (EDM): | + |
Synchronization: | Optical, without separate synchronization |
Restart interlock: | + |
Resolution: | 34 mm |
Automatic beam coding: | + |
Type: | Type 2 (IEC 61496) |
PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
Weight: | 420 g |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Protection class: | III (EN 61140) |
Protective field height: | 1,200 mm |
Switching current: | 300 mA |
Typical range: | 0 m ... 8 m |
Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
Switching voltage LOW: | 2 V DC |
Cascaded: | - |
Test rate (internal test): | 58 /s |
Display elements: | LEDs |
Ripple: | ≤ 10 % |
External device monitoring (delivery status): | Deactivated |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Maximum demand rate: | 34 /min (EN ISO 13849) |
Safe SICK device communication via EFI/SDL: | - |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Response time: | ≤ 13 ms |
Ambient operating temperature: | -20 °C ... +55 °C |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Enclosure rating: | IP 65 (EN 60529) |
Power consumption: | ≤ 3 A |
Configuration method: | Hard wired |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Air humidity: | 15 % ... 95 %, non-condensing |
Buy Sick C2MT-12034BBC03FE0 with the best possible price and delivery terms on eltra-trade.com
Discover a wide variety of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.
People also buy
Comments
No comments yet