Specification:

Part Number1207865
Shock resistance:10 g, 16 ms (EN 60068-2-27)
TM (mission time):20 a (EN ISO 13849)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Beam coding:+
Connection type:Male connector M12, 5-pin
Cable length:700 mm
Category:Category 2 (EN ISO 13849)
Permitted cable length:≤ 20 m
Scanning range:0 m ... 6 m
Conductor cross-section:0.34 mm?
Restart interlock (delivery status):Deactivated
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Storage temperature:-25 °C ... +70 °C
External device monitoring (EDM):+
Synchronization:Optical, without separate synchronization
Restart interlock:+
Resolution:34 mm
Automatic beam coding:+
Type:Type 2 (IEC 61496)
PFHd:Standalone system: 2.4  1E-08 (EN ISO 13849)
Weight:420 g
Housing material:Aluminum alloy ALMGSI 0.5
Protection class:III (EN 61140)
Protective field height:1,200 mm
Switching current:300 mA
Typical range:0 m ... 8 m
Safety integrity level:SIL1 (IEC 61508)
SILCL1 (EN 62061)
Performance level:PL c (EN ISO 13849), Pay attention to optical characteristics!
Switching voltage LOW:2 V DC
Cascaded:-
Test rate (internal test):58 /s
Display elements:LEDs
Ripple:≤ 10 %
External device monitoring (delivery status):Deactivated
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Maximum demand rate:34 /min (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Response time:≤ 13 ms
Ambient operating temperature:-20 °C ... +55 °C
Housing cross-section (incl. system connection):15 mm x 32 mm
Enclosure rating:IP 65 (EN 60529)
Power consumption:≤ 3 A
Configuration method:Hard wired
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Air humidity:15 % ... 95 %, non-condensing

Buy Sick C2MT-12034BBC03FE0 with the best possible price and delivery terms on eltra-trade.com

Discover a wide variety of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment