Sick C4MT-01214ABB03BB0
Light curtains

Sick C4MT-01214ABB03BB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-01214ABB03BB0
722.70
-
+
Total price: 722.70
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1206951
Protection class:III (EN 61140)
Typical range:0 m ... 5 m
Power consumption:≤ 3 A
Storage temperature:-25 °C ... +70 °C
Cascaded:-
Resolution:14 mm
Cable length:160 mm
Restart interlock:+
Switching current:300 mA
Ripple:≤ 10 %
Safe state in the event of a fault:At least one OSSD is in the OFF state.
External device monitoring (EDM):+
Permitted cable length:≤ 20 m
Response time:≤ 14 ms
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Enclosure rating:IP 65 (EN 60529)
Ambient operating temperature:-20 °C ... +55 °C
Scanning range:0 m ... 4 m
Type:Type 4 (IEC 61496)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Connection type:Male connector M12, 5-pin
Protective field height:120 mm
Weight:50 g
Synchronization:Optical, without separate synchronization
Housing cross-section (incl. system connection):15 mm x 32 mm
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Restart interlock (delivery status):Deactivated
Housing material:Aluminum alloy ALMGSI 0.5
Performance level:PL e (EN ISO 13849)
Automatic beam coding:+
Display elements:LEDs
Beam coding:+
Switching voltage LOW:2 V DC
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
External device monitoring (delivery status):Deactivated
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
TM (mission time):20 a (EN ISO 13849)
Category:Category 4 (EN ISO 13849)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Conductor cross-section:0.34 mm?
Air humidity:15 % ... 95 %, non-condensing
Configuration method:Hard wired

Buy Sick C4MT-01214ABB03BB0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a global leader in industrial automation supply. Our extensive catalog includes top brands, with worldwide delivery and competitive pricing. We focus on customer satisfaction and reliability. Experience our exceptional service and support for all your automation needs.

Comments

No comments yet