Sick C4MT-01214ABB04BE0
Light curtains

Sick C4MT-01214ABB04BE0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-01214ABB04BE0
741.40
-
+
Total price: 741.40
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207115
Permitted cable length:≤ 20 m
Weight:50 g
Power consumption:≤ 3 A
Protection class:III (EN 61140)
Air humidity:15 % ... 95 %, non-condensing
Display elements:LEDs
Housing cross-section (incl. system connection):15 mm x 32 mm
External device monitoring (delivery status):Deactivated
Switching current:300 mA
Safe SICK device communication via EFI/SDL:-
Performance level:PL e (EN ISO 13849)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Response time:≤ 14 ms
Scanning range:0 m ... 4 m
Conductor cross-section:0.34 mm?
Cascaded:+
Resolution:14 mm
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Synchronization:Optical, without separate synchronization
Housing material:Aluminum alloy ALMGSI 0.5
Restart interlock (delivery status):Deactivated
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
External device monitoring (EDM):+
Ambient operating temperature:-20 °C ... +55 °C
Enclosure rating:IP 65 (EN 60529)
Switching voltage LOW:2 V DC
Ripple:≤ 10 %
Category:Category 4 (EN ISO 13849)
Configuration method:Hard wired
Typical range:0 m ... 5 m
Automatic beam coding:+
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Connection type:Male connector M12, 5-pin
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Restart interlock:+
PFHd:Cascaded systems: 1.3  1E-08 (EN ISO 13849)
Beam coding:+
Type:Type 4 (IEC 61496)
Protective field height:120 mm
Connection type extension connection:Female connector M12, 5-pin
Storage temperature:-25 °C ... +70 °C
Cable length:160 mm
TM (mission time):20 a (EN ISO 13849)

Buy Sick C4MT-01214ABB04BE0 with the best possible price and delivery terms on eltra-trade.com

Discover a wide selection of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment