Sick C4MT-01224ABB03BB0
Light curtains

Sick C4MT-01224ABB03BB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-01224ABB03BB0
695.20
-
+
Total price: 695.20
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207318
Shock resistance:10 g, 16 ms (EN 60068-2-27)
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Restart interlock:+
Switching current:300 mA
Housing cross-section (incl. system connection):15 mm x 32 mm
Housing material:Aluminum alloy ALMGSI 0.5
Storage temperature:-25 °C ... +70 °C
Connection type:Male connector M12, 5-pin
Category:Category 4 (EN ISO 13849)
Cascaded:-
Synchronization:Optical, without separate synchronization
Enclosure rating:IP 65 (EN 60529)
Safe SICK device communication via EFI/SDL:-
Display elements:LEDs
Type:Type 4 (IEC 61496)
Power consumption:≤ 3 A
Performance level:PL e (EN ISO 13849)
Configuration method:Hard wired
Air humidity:15 % ... 95 %, non-condensing
Beam coding:+
External device monitoring (EDM):+
Protection class:III (EN 61140)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Switching voltage LOW:2 V DC
External device monitoring (delivery status):Deactivated
Cable length:160 mm
Resolution:24 mm
TM (mission time):20 a (EN ISO 13849)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Ripple:≤ 10 %
Conductor cross-section:0.34 mm?
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Restart interlock (delivery status):Deactivated
Response time:≤ 13 ms
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Automatic beam coding:+
Weight:50 g
Permitted cable length:≤ 20 m
Typical range:0 m ... 5 m
Protective field height:120 mm
Scanning range:0 m ... 4 m
Ambient operating temperature:-20 °C ... +55 °C
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)

Buy Sick C4MT-01224ABB03BB0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.

Comments

No comments yet

Write a comment