Sick C4MT-01234ABB03BB0
Light curtains

Sick C4MT-01234ABB03BB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-01234ABB03BB0
667.70
-
+
Total price: 667.70
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207334
Housing cross-section (incl. system connection):15 mm x 32 mm
Protective field height:120 mm
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Restart interlock:+
Typical range:0 m ... 5 m
Scanning range:0 m ... 4 m
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Resolution:34 mm
Air humidity:15 % ... 95 %, non-condensing
Restart interlock (delivery status):Deactivated
Ambient operating temperature:-20 °C ... +55 °C
Cascaded:-
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Permitted cable length:≤ 20 m
Housing material:Aluminum alloy ALMGSI 0.5
Automatic beam coding:+
Cable length:160 mm
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Category:Category 4 (EN ISO 13849)
Power consumption:≤ 3 A
Switching voltage LOW:2 V DC
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Configuration method:Hard wired
External device monitoring (delivery status):Deactivated
Response time:≤ 13 ms
Storage temperature:-25 °C ... +70 °C
Performance level:PL e (EN ISO 13849)
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Conductor cross-section:0.34 mm?
External device monitoring (EDM):+
Synchronization:Optical, without separate synchronization
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Safe SICK device communication via EFI/SDL:-
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Ripple:≤ 10 %
Weight:50 g
Protection class:III (EN 61140)
Enclosure rating:IP 65 (EN 60529)
Display elements:LEDs
Switching current:300 mA
Type:Type 4 (IEC 61496)
Beam coding:+
Connection type:Male connector M12, 5-pin

Buy Sick C4MT-01234ABB03BB0 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an electrical equipment shop. We have the status of the official representative of many European brands. We deliver to any country in the world. Our company is not an official distributor of all brands, but we can offer you competitive prices for all items in our catalog. We provide accurate delivery time information at the very beginning. We are the partner who can trust.