Sick C4MT-01814ABB03BE0
Light curtains

Sick C4MT-01814ABB03BE0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-01814ABB03BE0
806.30
-
+
Total price: 806.30
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207097
Shock resistance:10 g, 16 ms (EN 60068-2-27)
External device monitoring (EDM):+
Protection class:III (EN 61140)
Type:Type 4 (IEC 61496)
Cable length:160 mm
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Conductor cross-section:0.34 mm?
Safe SICK device communication via EFI/SDL:-
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
External device monitoring (delivery status):Deactivated
Cascaded:-
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
TM (mission time):20 a (EN ISO 13849)
Response time:≤ 14 ms
Permitted cable length:≤ 20 m
Restart interlock:+
Scanning range:0 m ... 4 m
Display elements:LEDs
Protective field height:180 mm
Restart interlock (delivery status):Deactivated
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Weight:75 g
Enclosure rating:IP 65 (EN 60529)
Beam coding:+
Housing cross-section (incl. system connection):15 mm x 32 mm
Housing material:Aluminum alloy ALMGSI 0.5
Power consumption:≤ 3 A
Air humidity:15 % ... 95 %, non-condensing
Typical range:0 m ... 5 m
Category:Category 4 (EN ISO 13849)
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Synchronization:Optical, without separate synchronization
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Switching voltage LOW:2 V DC
Resolution:14 mm
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Configuration method:Hard wired
Switching current:300 mA
Automatic beam coding:+
Performance level:PL e (EN ISO 13849)
Ripple:≤ 10 %
Storage temperature:-25 °C ... +70 °C
Ambient operating temperature:-20 °C ... +55 °C
Connection type:Male connector M12, 5-pin

Buy Sick C4MT-01814ABB03BE0 with the best possible price and delivery terms on eltra-trade.com

Discover a wide variety of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment