  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-03614ABB03DE0
1030.70
-
+
Total price: 1030.70
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207100
Power consumption:≤ 3 A
Category:Category 4 (EN ISO 13849)
Housing cross-section (incl. system connection):15 mm x 32 mm
Type:Type 4 (IEC 61496)
Conductor cross-section:0.34 mm?
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Cable length:350 mm
Storage temperature:-25 °C ... +70 °C
Switching current:300 mA
Air humidity:15 % ... 95 %, non-condensing
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Configuration method:Hard wired
Automatic beam coding:+
External device monitoring (delivery status):Deactivated
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Restart interlock:+
Connection type:Male connector M12, 5-pin
Typical range:0 m ... 5 m
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Protective field height:360 mm
Scanning range:0 m ... 4 m
Beam coding:+
Ambient operating temperature:-20 °C ... +55 °C
Protection class:III (EN 61140)
Restart interlock (delivery status):Deactivated
Permitted cable length:≤ 20 m
Synchronization:Optical, without separate synchronization
Ripple:≤ 10 %
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Cascaded:-
Switching voltage LOW:2 V DC
Resolution:14 mm
Display elements:LEDs
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Safe SICK device communication via EFI/SDL:-
Enclosure rating:IP 65 (EN 60529)
External device monitoring (EDM):+
Performance level:PL e (EN ISO 13849)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Response time:≤ 14 ms
Housing material:Aluminum alloy ALMGSI 0.5
Weight:135 g

Buy Sick C4MT-03614ABB03DE0 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online store of industrial automation equipment. Wе offer you a lot of spare parts that you cannot purchase on the market. We provide super fast delivery to any country. Become our partner and get great discounts. It is easy to make an order and to get the best quote. Send us a request and we will exceed your expectations.