Sick C4MT-04224ABB03DB0
Light curtains
We ship to United States of America!
- Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C4MT-04224ABB03DB0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1207322 |
Connection type: | Male connector M12, 5-pin |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Resolution: | 24 mm |
Enclosure rating: | IP 65 (EN 60529) |
Weight: | 155 g |
Category: | Category 4 (EN ISO 13849) |
Automatic beam coding: | + |
Protective field height: | 420 mm |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
PFHd: | Standalone system: 4.3 1E-09 (EN ISO 13849) |
Response time: | ≤ 13 ms |
Cascaded: | - |
Synchronization: | Optical, without separate synchronization |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Ripple: | ≤ 10 % |
Cable length: | 350 mm |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Permitted cable length: | ≤ 20 m |
TM (mission time): | 20 a (EN ISO 13849) |
External device monitoring (delivery status): | Deactivated |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
Ambient operating temperature: | -20 °C ... +55 °C |
Conductor cross-section: | 0.34 mm? |
Scanning range: | 0 m ... 4 m |
External device monitoring (EDM): | + |
Configuration method: | Hard wired |
Protection class: | III (EN 61140) |
Typical range: | 0 m ... 5 m |
Switching current: | 300 mA |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Storage temperature: | -25 °C ... +70 °C |
Air humidity: | 15 % ... 95 %, non-condensing |
Performance level: | PL e (EN ISO 13849) |
Restart interlock: | + |
Safe SICK device communication via EFI/SDL: | - |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Display elements: | LEDs |
Beam coding: | + |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Restart interlock (delivery status): | Deactivated |
Power consumption: | ≤ 3 A |
Switching voltage LOW: | 2 V DC |
Buy Sick C4MT-04224ABB03DB0 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. delivers top-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively and efficiently.