Sick C4MT-07214ABB04FE0
Light curtains

Sick C4MT-07214ABB04FE0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-07214ABB04FE0
1485.00
-
+
Total price: 1485.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207125
External device monitoring (EDM):+
TM (mission time):20 a (EN ISO 13849)
Response time:≤ 14 ms
PFHd:Cascaded systems: 1.3  1E-08 (EN ISO 13849)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Storage temperature:-25 °C ... +70 °C
Scanning range:0 m ... 4 m
Restart interlock:+
Safe SICK device communication via EFI/SDL:-
Beam coding:+
Housing material:Aluminum alloy ALMGSI 0.5
Synchronization:Optical, without separate synchronization
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Resolution:14 mm
Housing cross-section (incl. system connection):15 mm x 32 mm
Power consumption:≤ 3 A
External device monitoring (delivery status):Deactivated
Protective field height:720 mm
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Permitted cable length:≤ 20 m
Conductor cross-section:0.34 mm?
Protection class:III (EN 61140)
Category:Category 4 (EN ISO 13849)
Display elements:LEDs
Ambient operating temperature:-20 °C ... +55 °C
Connection type extension connection:Female connector M12, 5-pin
Weight:255 g
Connection type:Male connector M12, 5-pin
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Automatic beam coding:+
Cable length:700 mm
Air humidity:15 % ... 95 %, non-condensing
Cascaded:+
Ripple:≤ 10 %
Enclosure rating:IP 65 (EN 60529)
Performance level:PL e (EN ISO 13849)
Configuration method:Hard wired
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Switching voltage LOW:2 V DC
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Switching current:300 mA
Type:Type 4 (IEC 61496)
Restart interlock (delivery status):Deactivated
Typical range:0 m ... 5 m

Buy Sick C4MT-07214ABB04FE0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers reliable industrial control products. Our extensive inventory and worldwide delivery ensure you get the parts you need quickly. We pride ourselves on excellent customer service and competitive pricing. Contact us today to find out how we can support your business.

Comments

No comments yet

Write a comment