Sick C4MT-07814ABB03FE0
Safety light curtains

Sick C4MT-07814ABB03FE0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-07814ABB03FE0
1549.90
-
+
Total price: 1549.90
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207107
Connection type:Male connector M12, 5-pin
Resolution:14 mm
Synchronization:Optical, without separate synchronization
Display elements:LEDs
Scanning range:0 m ... 4 m
Switching voltage LOW:2 V DC
Power consumption:≤ 3 A
Enclosure rating:IP 65 (EN 60529)
Configuration method:Hard wired
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
External device monitoring (EDM):+
Protection class:III (EN 61140)
Cable length:700 mm
Housing material:Aluminum alloy ALMGSI 0.5
Air humidity:15 % ... 95 %, non-condensing
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Typical range:0 m ... 5 m
Performance level:PL e (EN ISO 13849)
Housing cross-section (incl. system connection):15 mm x 32 mm
Type:Type 4 (IEC 61496)
Ambient operating temperature:-20 °C ... +55 °C
External device monitoring (delivery status):Deactivated
Safe SICK device communication via EFI/SDL:-
Restart interlock:+
Restart interlock (delivery status):Deactivated
Ripple:≤ 10 %
Protective field height:780 mm
Weight:280 g
Storage temperature:-25 °C ... +70 °C
Beam coding:+
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Response time:≤ 17 ms
Switching current:300 mA
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Automatic beam coding:+
Category:Category 4 (EN ISO 13849)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
TM (mission time):20 a (EN ISO 13849)
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Conductor cross-section:0.34 mm²
Permitted cable length:≤ 20 m
Cascaded:-
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
  • Within the limits of VS.
  • Maximum power consumption of a host/guest/guest system with 1,200 mm protective field height and a resolution of 14 mm.
  • Applies to the voltage range between –30 V and +30 V.

Buy Sick C4MT-07814ABB03FE0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade is a known electrical equipment supplier. We offer a wide range of electronic automation products. We ship to any location in the world. We can offer you competitive prices for all items from our web catalog and Eltra Trade is always on time with the delivery time. We have the best ratio of speed, product quality and price.