Sick C4MT-08424ABB03FB0
Light curtains

Sick C4MT-08424ABB03FB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-08424ABB03FB0
1458.60
-
+
Total price: 1458.60
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1207328
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Enclosure rating:IP 65 (EN 60529)
Storage temperature:-25 °C ... +70 °C
Power consumption:≤ 3 A
Restart interlock:+
Protection class:III (EN 61140)
Switching current:300 mA
Protective field height:840 mm
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Configuration method:Hard wired
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
TM (mission time):20 a (EN ISO 13849)
External device monitoring (EDM):+
Conductor cross-section:0.34 mm?
Ripple:≤ 10 %
Cable length:700 mm
Beam coding:+
Performance level:PL e (EN ISO 13849)
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Synchronization:Optical, without separate synchronization
Category:Category 4 (EN ISO 13849)
Response time:≤ 13 ms
Weight:300 g
Cascaded:-
Connection type:Male connector M12, 5-pin
Typical range:0 m ... 5 m
Type:Type 4 (IEC 61496)
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Resolution:24 mm
Housing cross-section (incl. system connection):15 mm x 32 mm
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Housing material:Aluminum alloy ALMGSI 0.5
Air humidity:15 % ... 95 %, non-condensing
Switching voltage LOW:2 V DC
Automatic beam coding:+
Scanning range:0 m ... 4 m
Restart interlock (delivery status):Deactivated
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Ambient operating temperature:-20 °C ... +55 °C
Permitted cable length:≤ 20 m
Display elements:LEDs
External device monitoring (delivery status):Deactivated
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)

Buy Sick C4MT-08424ABB03FB0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. provides comprehensive industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.