Sick C4MT-09014ABB03FB0
Light curtains
We ship to United States of America!
- Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C4MT-09014ABB03FB0
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1206964 |
Restart interlock: | + |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Ambient operating temperature: | -20 °C ... +55 °C |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Connection type: | Male connector M12, 5-pin |
External device monitoring (EDM): | + |
Power consumption: | ≤ 3 A |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Switching current: | 300 mA |
Permitted cable length: | ≤ 20 m |
Switching voltage LOW: | 2 V DC |
Resolution: | 14 mm |
Conductor cross-section: | 0.34 mm? |
Cable length: | 700 mm |
Performance level: | PL e (EN ISO 13849) |
Category: | Category 4 (EN ISO 13849) |
PFHd: | Standalone system: 4.3 1E-09 (EN ISO 13849) |
Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
Typical range: | 0 m ... 5 m |
Display elements: | LEDs |
Protection class: | III (EN 61140) |
Protective field height: | 900 mm |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
Ripple: | ≤ 10 % |
External device monitoring (delivery status): | Deactivated |
Beam coding: | + |
Synchronization: | Optical, without separate synchronization |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Restart interlock (delivery status): | Deactivated |
Response time: | ≤ 17 ms |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Automatic beam coding: | + |
Safe SICK device communication via EFI/SDL: | - |
Weight: | 320 g |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
TM (mission time): | 20 a (EN ISO 13849) |
Scanning range: | 0 m ... 4 m |
Enclosure rating: | IP 65 (EN 60529) |
Air humidity: | 15 % ... 95 %, non-condensing |
Cascaded: | - |
Configuration method: | Hard wired |
Type: | Type 4 (IEC 61496) |
Storage temperature: | -25 °C ... +70 °C |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Buy Sick C4MT-09014ABB03FB0 with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services.
People also buy
Comments
No comments yet