Sick C4MT-10814ABB03FB0
Light curtains

Sick C4MT-10814ABB03FB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-10814ABB03FB0
1910.70
-
+
Total price: 1910.70
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1206967
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Switching current:300 mA
Power consumption:≤ 3 A
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
TM (mission time):20 a (EN ISO 13849)
Automatic beam coding:+
Safe SICK device communication via EFI/SDL:-
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Switching voltage LOW:2 V DC
Ripple:≤ 10 %
Protective field height:1,080 mm
Permitted cable length:≤ 20 m
Cable length:700 mm
External device monitoring (EDM):+
Connection type:Male connector M12, 5-pin
Weight:380 g
External device monitoring (delivery status):Deactivated
Storage temperature:-25 °C ... +70 °C
Type:Type 4 (IEC 61496)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Performance level:PL e (EN ISO 13849)
Scanning range:0 m ... 4 m
Category:Category 4 (EN ISO 13849)
Enclosure rating:IP 65 (EN 60529)
Restart interlock (delivery status):Deactivated
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Display elements:LEDs
Protection class:III (EN 61140)
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Housing cross-section (incl. system connection):15 mm x 32 mm
Resolution:14 mm
Response time:≤ 17 ms
Housing material:Aluminum alloy ALMGSI 0.5
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Cascaded:-
Ambient operating temperature:-20 °C ... +55 °C
Air humidity:15 % ... 95 %, non-condensing
Restart interlock:+
Typical range:0 m ... 5 m
Conductor cross-section:0.34 mm?
Configuration method:Hard wired
Synchronization:Optical, without separate synchronization
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Beam coding:+

Buy Sick C4MT-10814ABB03FB0 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. provides high-quality industrial control products. Our extensive inventory ensures you find the parts you need, with prompt worldwide delivery. We offer competitive prices and personalized service. Get in touch today to see how we can support your business.

Comments

No comments yet