Sick C4MT-12014ABB03FB0
Light curtains

Sick C4MT-12014ABB03FB0
We ship to United States of America!
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-12014ABB03FB0
2059.20
-
+
Total price: 2059.20
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1206969
Weight:420 g
Enclosure rating:IP 65 (EN 60529)
TM (mission time):20 a (EN ISO 13849)
Protection class:III (EN 61140)
Protective field height:1,200 mm
External device monitoring (delivery status):Deactivated
Safe state in the event of a fault:At least one OSSD is in the OFF state.
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
External device monitoring (EDM):+
Type:Type 4 (IEC 61496)
Category:Category 4 (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Display elements:LEDs
Housing cross-section (incl. system connection):15 mm x 32 mm
Switching voltage LOW:2 V DC
Housing material:Aluminum alloy ALMGSI 0.5
Synchronization:Optical, without separate synchronization
Storage temperature:-25 °C ... +70 °C
Resolution:14 mm
Configuration method:Hard wired
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Scanning range:0 m ... 4 m
Power consumption:≤ 3 A
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Restart interlock (delivery status):Deactivated
Typical range:0 m ... 5 m
Conductor cross-section:0.34 mm?
Cable length:700 mm
Permitted cable length:≤ 20 m
Connection type:Male connector M12, 5-pin
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Automatic beam coding:+
Performance level:PL e (EN ISO 13849)
Beam coding:+
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Switching current:300 mA
Ripple:≤ 10 %
Ambient operating temperature:-20 °C ... +55 °C
Restart interlock:+
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Cascaded:-
Response time:≤ 17 ms
Air humidity:15 % ... 95 %, non-condensing

Buy Sick C4MT-12014ABB03FB0 with the best possible price and delivery terms on eltra-trade.com