Sick DL100-23HA2103
Distance sensors

Sick DL100-23HA2103
  • Measuring range up to 300 m (dependent on type)
  • Numerous fieldbus interfaces
  • Pre-failure notification and diagnostic data available
Item Number: DL100-23HA2103
4059.00
-
+
Total price: 4059.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1052701
Effect of air pressure:0.3 ppm/hPa
Resolution:0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Multifunctional input (MF) :1 x MF1
Laser class:2 (EN 60825-1 / CDRH)
Weight :Ca. 800 g ... 1,600 g
Modulation frequency:Fix
Typ. light spot size (distance):5 mm (+ 2 mm x distance in m)
Connection type:Male connector, M12, SPEEDCON™ compatible
Ambient temperature:Operation with cooling case: -40 ... +75 °C
Storage: -40 ... +75 °C
Operation with heating: -40 ... +55 °C
Supply voltage Vs:DC 18 V ... 30 V, limit values
Repeatability :2 mm
Switching output :B (push/pull)
MF1, MF2
Max. movement speed:30 m/s
Indication:6 digit 5 x 7 dot matrix display, LEDs
Protection class:III
Measuring range:0.15 m ... 300 m, On reflective tape "Diamond Grade"
Acceleration (max.):15 m/s?
Output current IA :≤ 100 mA
Internal measurement cycle:1 ms
Ripple :5 Vpp
Light source :Laser, red
Enclosure rating:IP 65
Mechanical load:Noise: EN 600 68-2-64
Shock: EN 600 68-2-27
Sine: EN 600 68-2-6
Electromagnetic compatibility (EMC) :EN 61000-6-2 / EN 61000-6-4
Housing material:Aluminum/zinc die-cast
Accuracy :± 3 mm
Dead time:2 ms
Data interface:RS-422
Power consumption:At 24 V DC < 1,000 mA
Output time:Synchronous to PLC request (dependent on interfaces)
Effect of air temperature:1 ppm/K
Temperature drift:Typ. 0.1 mm/K
Initialization time :Typ. 1.5 s

Comments

No comments yet

Write a comment