Sick DT35-B15551
Mid range distance sensor

Sick DT35-B15551
  • Maximum reliability, immunity to ambient light, and best price/performance ratio thanks to HDDM™ technology
  • Reliable detection and broad measuring range of 0.05 m to 12 m
  • Very good accuracy of ±10 mm
Item Number: DT35-B15551
528.00
-
+
Total price: 528.00
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1057651
Laser service life (MTTF at 25 °C):100,000 h
Enclosure rating:IP 65, IP 67
Protection class:III
Ambient temperature :Operation: -30 ... +55 °C, Storage: -40 ... +75 °C
Resolution:0.1 mm
Measuring range :50 mm ... 12,000 mm, 90 % remision
50 mm ... 3,100 mm, 6 % remission
50 mm ... 5,300 mm, 18 % remission
Switching frequency :166 Hz / 50 Hz / 25 Hz / 12 Hz / 3 Hz
Connection type:Male connector, M12, 5-pin
Light source :Laser, red
Supply voltage Vs :DC 12 V ... 30 V
Hysteresis :0 mm ... 11,950 mm
Multifunctional input (MF) :1 x
Typ. light spot size (distance):15 mm x 15 mm (at 2 m)
Output time :2 ms / 4 ms / 8 ms / 16 ms / 64 ms
Resolution analog output:12 bit
Data interface:IO-Link



Indication:LEDs
Accuracy :Typ. ± 10 mm
Additional function:Set speed: Super Fast ... Super Slow
IO-Link
Reset to factory default
Output Q2, selectable: 4 mA ... 20 mA / 0 V … 10 V / switching output
Multifunctional input: laser off / external teach / deactivated
Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB)
Teach-in of analog output and invertible analog output
Teach-in of switching output and switching output invertible
Initialization time:≤ 500 ms
Power consumption :≤ 1.7 W
Ripple :≤ 5 Vpp
Typ. ambient light safety:40 klx
Laser class:1 (EN 60825-1)
Switching output :1 x / 2 x push-pull: PNP/NPN (100 mA), IO-Link
Weight:65 g
Shock resistance:EN 60068-2-27
Response time :4.5 ms / 12.5 ms / 24.5 ms / 48.5 ms / 192.5 ms
Analog output :1 x 4 mA ... 20 mA (≤ 450 &;937;) / 1 x 0 V … 10 V (≥ 50 k&;937;) / -
Vibration resistance:EN 60068-2-6 / EN 60068-2-64
Repeatability :0.5 mm ... 5 mm
Warm-up time:≤ 20 min
Housing material:Plastic (ABS and PC)
acrylic glass (PMMA)