Specification:
Part Number | 1061712 |
Power consumption: | 55 mA |
Type of supply voltage: | SELV |
PFHd: | 0.76 1E-09 (EN ISO 13849) |
Safety device connection: | Dual-channel equivalent electro-mechanical safety switch (EMSS) |
Short-circuit: | Monitoring via Flexi Loop node |
Electromagnetic compatibility (EMC): | Class A (EN 61000-6-2, EN 55011) |
Discrepancy errors: | Monitoring via Flexi Loop node |
Shock resistance (single shock): | 30 g, 11 ms (EN 60068-2-27) |
Sequence errors: | Monitoring via Flexi Loop node |
Dimensions (W x H x D): | 68.15 mm x 45 mm x 18 mm |
Enclosure rating: | IP 65, IP 67 (EN 60529) |
Connection type safety device: | Female connector M12, 8-pin |
Storage temperature: | -25 °C ... +70 °C |
Ambient operating temperature: | -25 °C ... +55 °C |
Cross-circuit: | Monitoring via Flexi Loop node |
TM (mission time): | 20 a (EN ISO 13849) |
Connection type Flexi Loop input: | Male connector M12, 5-pin |
Power supply output for external devices: | + |
Category: | Category 4 (EN ISO 13849-1) |
Flexi Loop output: | To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element. |
Safe state in the event of a fault: | The sensor cascade has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Shock resistance (continuous shock): | 10 g, 16 ms (EN 60068-2-64) |
IO-Link: | - |
Connection type Flexi Loop output: | Female connector M12, 5-pin |
Supply voltage Vs: | 24 V DC (16.8 V DC ... 30 V DC) |
Flexi Loop input: | To connect a Flexi Loop predecessor module, or to connect a Flexi Loop string with the safety controller Flexi Soft. |
Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
Performance level: | PL e (EN ISO 13849-1) |
Weight: | 28 g (± 5 %) |
Number of non-safe outputs: | 1 |
Number of non-safe inputs: | 1 |
Protection class: | III (EN 61140) |