Sick FLN-OSSD1000105

Sick FLN-OSSD1000105
We ship to United States of America!
  • Ability to cascade 32 sensors with up to 30 m per segment in compliance with performance level e
  • Compatible with sensors from all manufacturers
  • Detailed diagnostic information
Item Number: FLN-OSSD1000105
98.17
-
+
Total price: 98.17
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Specification:

Part Number1061709
Power consumption:45 mA
Electromagnetic compatibility (EMC):Class A (EN 61000-6-2, EN 55011)
Connection type safety device:Female connector M12, 5-pin
Storage temperature:-25 °C ... +70 °C
Flexi Loop output:To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element.
Performance level:PL e (EN ISO 13849-1)
IO-Link:-
Shock resistance (single shock):30 g, 11 ms (EN 60068-2-27)
Connection type Flexi Loop output:Female connector M12, 5-pin
TM (mission time):20 a (EN ISO 13849)
Flexi Loop input:To connect a Flexi Loop predecessor module, or to connect a Flexi Loop string with the safety controller Flexi Soft.
Number of non-safe outputs:0
Safety device connection:Safety sensor with dual-channel OSSD outputs
Enclosure rating:IP 65, IP 67 (EN 60529)
Power supply output for external devices:+
Category:Category 4 (EN ISO 13849-1)
Protection class:III (EN 61140)
Dimensions (W x H x D):68.15 mm x 45 mm x 18 mm
Type of supply voltage:SELV
PFHd:0.76 1E-09 (EN ISO 13849)
Cross-circuit:Monitoring via OSSD device
Supply voltage Vs:24 V DC (16.8 V DC ... 30 V DC)
Safe state in the event of a fault:The sensor cascade has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.
Short-circuit:Monitoring via OSSD device
Sequence errors:Monitoring via Flexi Loop node
Weight:28 g (± 5 %)
Ambient operating temperature:-25 °C ... +55 °C
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Shock resistance (continuous shock):10 g, 16 ms (EN 60068-2-64)
Number of non-safe inputs:1
Discrepancy errors:Monitoring via Flexi Loop node
Connection type Flexi Loop input:Male connector M12, 5-pin

Buy Sick FLN-OSSD1000105 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a global leader in industrial automation supply. Our extensive catalog includes top brands, with worldwide delivery and competitive pricing. We focus on customer satisfaction and reliability. Experience our exceptional service and support for all your automation needs.

Comments

No comments yet

Write a comment