Sick FUM-H015F1MB50000
Flow Ultrasonic meter

Sick FUM-H015F1MB50000
We ship to United States of America!
FUM-H015F1MB50000 FLOW ULTRASONIC METER art. 1082020
Item Number: FUM-H015F1MB50000
4051.32
-
+
Total price: 4051.32
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick FUM-H015F1MB50000

Datasheet:

  • Article: 1082020
  • Measurement principle: Ultrasonic sensor
  • Measurement method: Ultrasound
  • Media: Conductive and non-conductive liquids
  • li>Nominal measuring tube diameter: DN 15
  • Operating temperature: 0 °C ... +95 °C, up to 143 °C for 60 minutes
  • Operating pressure: –0, 5 bar ... 16 bar
  • Communication interface: IO-Link IO-Link V1.1
  • EHEDG certificate: ?
  • cULus certificate: ?
  • RoHS certificate: ?
  • FDA: ?
  • Temperature measurement: ?
  • Minimum flow: ? 0.5 l/min
  • Maximum flow: 0 l/min ... 80 l/min
  • Inlet line: 5 x DN (7.5 cm)
  • Outlet line: 3 x DN (4.5 cm)
  • Electrical conductivity: Unlimited
  • Measuring element accuracy: ± 1% of measured value
  • Reproducibility: 0.5%
  • Resolution: 10 ml/min
  • Rating: 12 ms
  • Supply voltage: 12 V DC ... 30 V DC
  • Power consumption: < 3 W without output load
  • Initialization time: ? 5 s
  • Protection class: III
  • Connection type: Circular connector M12 x 1, 5-pin
  • Output signal: 1 x analogue output: 4–20 mA, 2 x digital output/input (configurable)
  • Output load: 4 mA ... 20 mA, 500 Ohm at Uv 15 ? V, 350 Ohm at Uv 12 ? V
  • Lower signal level: 3.5 mA ... 3.8 mA
  • Upper signal level: 21.5 mA. .. 20.5 mA
  • Digital output: ? 100 mA
  • Pulse output signal: 50 µs ... 2 s
  • Pulse output / Frequency output: 0–10 kHz
  • Signal voltage HIGH: > (UV - 4 V)
  • Signal voltage LOW: < 3 V
  • Inductive load: < 1 H
  • Capacitive load: < 100 nF, < 2.5 nF (IO-Link),
  • EMC: EN 61326-1, EN 61326-2-3
  • Limit of switching inputs: Voltage HIGH > 16.0 V, Voltage LOW < 4.0 V
  • Mean time to failure: > 63 years
  • Technical connections: DIN 11851 DN 15
  • Materials in contact with the medium: Stainless steel 1.4404 (Ra ? 0.8 µm)
  • Housing material: Stainless steel 1.4305
  • Housing design: With sight glass made of PMMA (acrylic glass)
  • Protection type: IP67/IP69 (DIN EN 60529)
  • Weight: Approx. 2 kg
  • Temperature range during operation: 0 °C ... +60 °C
  • Temperature range during storage: –40 °C ... +80 °C
  • Category:Flow sensors
  • Series:DOSIC®
  • Measuring principle: ultrasonic sensor

Buy Sick FUM-H015F1MB50000 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers comprehensive industrial automation solutions. With a wide selection of products and express delivery options, we meet your demands efficiently. Our commitment to quality and customer satisfaction sets us apart. Experience the difference with our reliable services.

Comments

No comments yet

Write a comment