Sick FUM-H015F1MB50000
Flow Ultrasonic meter

Sick FUM-H015F1MB50000
We ship to United States of America!
FUM-H015F1MB50000 FLOW ULTRASONIC METER art. 1082020
Item Number: FUM-H015F1MB50000
4051.32
-
+
Total price: 4051.32
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick FUM-H015F1MB50000

Datasheet:

  • Article: 1082020
  • Measurement principle: Ultrasonic sensor
  • Measurement method: Ultrasound
  • Media: Conductive and non-conductive liquids
  • li>Nominal measuring tube diameter: DN 15
  • Operating temperature: 0 °C ... +95 °C, up to 143 °C for 60 minutes
  • Operating pressure: –0, 5 bar ... 16 bar
  • Communication interface: IO-Link IO-Link V1.1
  • EHEDG certificate: ?
  • cULus certificate: ?
  • RoHS certificate: ?
  • FDA: ?
  • Temperature measurement: ?
  • Minimum flow: ? 0.5 l/min
  • Maximum flow: 0 l/min ... 80 l/min
  • Inlet line: 5 x DN (7.5 cm)
  • Outlet line: 3 x DN (4.5 cm)
  • Electrical conductivity: Unlimited
  • Measuring element accuracy: ± 1% of measured value
  • Reproducibility: 0.5%
  • Resolution: 10 ml/min
  • Rating: 12 ms
  • Supply voltage: 12 V DC ... 30 V DC
  • Power consumption: < 3 W without output load
  • Initialization time: ? 5 s
  • Protection class: III
  • Connection type: Circular connector M12 x 1, 5-pin
  • Output signal: 1 x analogue output: 4–20 mA, 2 x digital output/input (configurable)
  • Output load: 4 mA ... 20 mA, 500 Ohm at Uv 15 ? V, 350 Ohm at Uv 12 ? V
  • Lower signal level: 3.5 mA ... 3.8 mA
  • Upper signal level: 21.5 mA. .. 20.5 mA
  • Digital output: ? 100 mA
  • Pulse output signal: 50 µs ... 2 s
  • Pulse output / Frequency output: 0–10 kHz
  • Signal voltage HIGH: > (UV - 4 V)
  • Signal voltage LOW: < 3 V
  • Inductive load: < 1 H
  • Capacitive load: < 100 nF, < 2.5 nF (IO-Link),
  • EMC: EN 61326-1, EN 61326-2-3
  • Limit of switching inputs: Voltage HIGH > 16.0 V, Voltage LOW < 4.0 V
  • Mean time to failure: > 63 years
  • Technical connections: DIN 11851 DN 15
  • Materials in contact with the medium: Stainless steel 1.4404 (Ra ? 0.8 µm)
  • Housing material: Stainless steel 1.4305
  • Housing design: With sight glass made of PMMA (acrylic glass)
  • Protection type: IP67/IP69 (DIN EN 60529)
  • Weight: Approx. 2 kg
  • Temperature range during operation: 0 °C ... +60 °C
  • Temperature range during storage: –40 °C ... +80 °C
  • Category:Flow sensors
  • Series:DOSIC®
  • Measuring principle: ultrasonic sensor

Buy Sick FUM-H015F1MB50000 with the best possible price and delivery terms on eltra-trade.com