Sick ICR840-2C1020 Image-based code readers

Sick ICR840-2C1020
Item Number: ICR840-2C1020
  • Configure with live image and auto setup
  • Fast, omni-directional reading of printed and direct marked 1D and 2D codes
  • Rapid image and data transfer via Ethernet
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Sick ICR840-2C1020 is outdated.

Specification:

Part Number1042885
Remark (DeviceNet):Optional via external connection module (CDM + CMF)
Data transmission rate (CAN bus):10 kbit/s ... 1 Mbit/s
Remark (PROFIBUS DP):Optional via external connection module (CDM + CMF)
Shock resistance:EN 60068-2-27
Permissible relative humidity:± 90 %, non-condensing
Electromagnetic compatibility (EMC):EN 61000-6-2 / EN 61000-6-4
Switching outputs:2 (Result 1 NPN, Result 2 PNP)
Reading pulse:Non-powered, Switching inputs, Serial interface
Function (Serial (RS-232)):Host, AUX
No. of codes per scan:1 ... 50
No. of codes per reading interval:1 ... 50
Sensor resolution:1,280 px x 1,024 px (1.3 Mpixel
Scanning frequency:25 Hz, at 1.3 megapixels resolution
CAN bus:+
Protocol (CAN bus):CANopen, CSN (SICK CAN Sensor Network)
2D code types:Data Matrix ECC200, GS1 Data-Matrix, QR code
Function (Ethernet):Host, AUX, image transmission
Focus position:115 mm
Version:Mid Range
MTBF:75,000 h
Housing:Die-cast zinc
Operating voltage:15 V DC ... 30 V DC
Optical indicators:6 LEDs (status displays)
Protection class:III (EN 61140)
Housing color:Light blue (RAL 5012)
Power consumption:13 W
Data transmission rate (Ethernet):10/100 Mbit
DeviceNet:+
Bar code types:Interleaved 2 of 5, Codabar, Code 128, Code 39, GS1-128 / EAN 128, Pharmacode, UPC / GTIN / EAN
Dimensions:112 mm x 80 mm x 39 mm
PROFIBUS DP:+
Ethernet:+
Data transmission rate (Serial (RS-232)):300 Baud ... 57,600 Baud, AUX: 9,600 Baud
Reading field:Side
Focus:Fixed focus
Acoustic indicators:Beeper/buzzer (can be switched off, can be assigned a function to signal a result)
No. of characters per reading interval:4,000
Function (CAN bus):SICK CAN sensor network (Master/Slave, Multiplexer)
Serial (RS-232):+
Protocol (Ethernet):TCP/IP, FTP (image transmission), PROFINET (optional via external connection module CDM)
Light source:Visible red light (lighting LEDs, 617 nm, ± 15 nm)
Ambient operating temperature:0 °C ... +40 °C
Vibration resistance:EN 60068-2-6
Electrical connection:1 x RJ45 female connector on device, cables with 15-pin D-sub HD male connector (0.9 m, ± 5 %)
Enclosure rating:IP 30, IP 65 (EN 60529)
Laser class:1 (EN 60825-1)
Switching inputs:2
Sensor:CMOS matrix sensor
Ambient light safety:2,000 lx, on bar code
Code resolution:≥0.15 mm
Reading distance:70 mm ... 210 mm
Weight:900 g, with connecting cable
Storage temperature:-20 °C ... +70 °C

Comments

No comments yet