Sick IMC12-04BPPVC0SB02
Inductive proximity sensor

Sick IMC12-04BPPVC0SB02
We ship to United States of America!
IMC12-04BPPVC0SB02 INDUCT.PROXIM.SENS. art. 1097434
Item Number: IMC12-04BPPVC0SB02
141.08
-
+
Total price: 141.08
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick IMC12-04BPPVC0SB02

Datasheet:

  • Article: 1097434
  • Case type: Cylindrical with thread
  • Thread size: M12 x 1
  • Diameter: Ш 12 mm
  • Sensing distance Sn: 0 mm ... 4 mm
  • Sensing distance ensured Sa: 3.24 mm
  • Switching modes: Single point
  • Switching frequency Qint.1 / Qint.2 on pin 2:: 1.000 Hz
  • Installation: Flush
  • Type of connection : M12 connector, 4-pin.
  • Switching output: PNP
  • Q/C output: switching output or IO-link mode
  • MFC output: switching output or input
  • Output function: Normally open
  • Electrical version: DC. current, 4-wire
  • Protection type: IP68, IP69K,
  • Special properties: IO-Link
  • Diagnostics: Chip temperature
  • Pin 2 configuration: Learn
  • Supply voltage: 10 V DC ... 30 V DC
  • Residual ripple: ? 10%
  • Voltage drop: ? 2 V
  • Current consumption: 35 mA
  • Hysteresis: 1% of programmed digital value
  • Reproducibility: ? 5%
  • Temperature deviation (from S r): ± 10%
  • EMC: According to EN 60947-5-2
  • DC current Ia: ? 200 mA
  • Short circuit protection: ?
  • Polarity inversion protection: ?
  • Suppression of switching pulse: ?
  • Shock and vibration resistance: 100 g/5 ms/500 cycles - 150 g/1 million cycles - 10...55 Hz, 1 mm/55...500 Hz/60 g
  • Operating temperature range: –40 ° C ... +75 °C
  • Housing material: Stainless steel V2A, DIN 1.4305 / AISI 303
  • Material, active surface: Plastic, LCP
  • Length body: 65 mm
  • Usable thread length: 48 mm
  • Max. tightening torque: Typ. 32 Nm
  • Supplied with: Fastening nut, stainless steel V2A, with locking gear (2 pcs.)
  • UL File No.: E181493
  • Teaching accuracy: +/- 3% of Sr
  • Resolution, typical (range): 10 µm (0 mm ... 1 mm), 20 µm (1 mm ... 3 mm), 40 µm (3 mm ... 4 mm),
  • Resolution, maximum (range): 20 ?m (0 mm ... 1 mm), 40 ?m (1 mm ... 3 mm), 75 ?m (3 mm ... 4 mm),
  • Communication interface: IO-Link V1.1
  • Communication interface, detailed description: COM2 (38.4 kBaud)
  • Cycle time: 5 ms
  • Process data length: 32 Bit
  • Process data structure: Bit 0 = digital signal QL1, Bit 1 = digital signal Q L2, Bit 2 = digital signal QInt3, Bit 3 = digital signal QInt4, Bit16 ... 31 = distance value,
  • Default settings: Switching point 1: set value 1, Output: normally open,
  • Note: The numerical set value for the switching point in mm is stored in the sensor
  • Set value 1: 4 mm
  • Set value 2: 3 mm
  • Set value 3: 2 mm
  • Set value 4: 1 mm
  • li>Stainless steel (V2A): Approx. 0.7
  • Aluminum (Al): Approx. 0.4
  • Copper (Cu): Approx. 0.3
  • Brass (Ms): Approx. 0.4
  • Note: For relevant graphic materials, see section. “Installation instructions”
  • B: 12 mm
  • C: 12 mm
  • D: 12 mm
  • F: 32 mm
  • Series:IMC
  • Sensing distance:4 mm
  • Output type:PNP
  • Installation:flush
  • Case type:cylindrical with thread
  • Output function:NC

Buy Sick IMC12-04BPPVC0SB02 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is fast developing company in automation instrumentation. Due to a wide range of brands, we allow you to refuse many other suppliers greatly saving your time. We provide delivery all over the world. We will help you to save money with our lowest prices. We are keeping you up-to-date with Tracking Numbers throughout the process. We always fulfill our obligations.

Comments

No comments yet