Sick LFP0500-GANMB
Level Fluid

Sick LFP0500-GANMB
We ship to United States of America!
LFP0500-GANMB LEVEL FLUID art. 1080619
Item Number: LFP0500-GANMB
1751.45
-
+
Total price: 1751.45
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick LFP0500-GANMB

Datasheet:

  • Article: 1080619
  • Media: Liquids
  • Measurement method: Limit value, continuous
  • Design: Standard
  • Probe length: 500 mm
  • Operating pressure: –1 bar ... 16 bar
  • Operating temperature: –20 °C ... +150 °C
  • UL Certified: ?
  • RoHS Certified: ?
  • IO-Link: ?
  • EHEDG Certified: ?
  • Measuring Element Accuracy: ± 5 mm
  • Reproducibility: ? 2 mm
  • Resolution: < 2 mm
  • Evaluation: < 400 ms
  • Dielectric constant: ? 5 in rod probe, ? 1.8 with coaxial pipe,
  • Electrical conductivity: Unlimited
  • Inactive area at technical connection: 25 mm
  • Inactive area at end probe: ? 10 mm
  • Mean time to failure: 194.3 years (EN ISO 13849-1)
  • Supply voltage: 12 V DC ... 30 V DC
  • Current consumption: ? 75 mA at 24 VDC without output load
  • Initialization time: ? 2 s
  • Protection class: III
  • Connection type: Cable entry M12 x 1, 5-pin
  • Cable length: 10 m
  • Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
  • Output load: 4–20 mA < 500 ? at Uv > 13.5 V, 4–20 mA < 400 ? at Uv > 12 V, 0–10 V > 750 Ohm at Uv 14 ? V
  • Hysteresis: Min. 2 mm, freely adjustable
  • Signal voltage HIGH: Uv - 2 V
  • Signal voltage LOW: ? 2 V
  • Output current: < 100 mA
  • Inductive load: < 1 H
  • Capacitive load: < 100 nF
  • Protection type: IP67: EN 60529, IP69K: ISO 20653
  • Temperature drift: < 0.1 mm/K
  • Lower signal level: 3.8 mA ... 4 mA, 0 V
  • Upper signal level : 20 mA ... 20.5 mA, 10.5 V
  • EMC: EN 61326-2-3, 2014/30/EU
  • Wetted materials: 1.4404 (Ra ? 0.8 µm), PEEK
  • Technical connections: G ѕ A
  • Housing material: 1.4305
  • Housing design: With sight glass made of PMMA ( acrylic glass)
  • Max. probe load: ? 6 Nm
  • Coaxial line length: 10 m
  • Operating temperature range: –20 °C ... +60 °C
  • Storage temperature range: –40 °C ... +80 °C
  • Outdoor use: Only with weatherproof cover
  • Category : Fill level sensors
  • Series: LFP Inox
  • Media: liquids
  • Measurement method: limit value, continuous

Buy Sick LFP0500-GANMB with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. delivers high-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively.

Comments

No comments yet

Write a comment