Sick LFP0560-G3NMB
Level Fluid

Sick LFP0560-G3NMB
We ship to United States of America!
LFP0560-G3NMB LEVEL FLUID art. 1113942
Item Number: LFP0560-G3NMB
1434.48
-
+
Total price: 1434.48
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick LFP0560-G3NMB

Datasheet:

  • Article: 1113942
  • Media: Liquids
  • Measurement method: Limit value, continuous
  • Design: Standard
  • Probe length: 560 mm
  • Operating pressure: –1 bar ... 16 bar
  • Operating temperature: –20 °C ... +150 °C
  • UL Certified: ?
  • RoHS Certified: ?
  • IO-Link: ?
  • EHEDG Certified: ?
  • 3-A: ?
  • Measuring element accuracy: ± 5 mm
  • Reproducibility: ? 2 mm
  • Resolution: < 2 mm
  • Rating: < 400 ms
  • Dielectric constant: ? 5 in rod probe, ? 1.8 with coaxial pipe,
  • Electrical conductivity: Unlimited
  • Inactive area on technical connection: 25 mm
  • Inactive area at the end of the probe: ? 10 mm
  • Mean time to failure: 194.3 years (EN ISO 13849-1)
  • Supply voltage: 12 V DC ... 30 V DC
  • Current consumption: ? 75 mA at 24 VDC without output load
  • Initialization time: ? 2 s
  • Protection class : III
  • Connection type: Circular connector M12 x 1, 5-pin
  • Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
  • Output load: 4–20 mA < 500 ? at Uv > 13.5 V, 4–20 mA < 400 ? at Uv > 12 V, 0–10 V > 750 Ohm at Uv 14 ? V
  • Hysteresis: Min. 2 mm, freely adjustable
  • Signal voltage HIGH: Uv - 2 V
  • Signal voltage LOW: ? 2 V
  • Output current: < 100 mA
  • Inductive load: < 1 H
  • Capacitive load: < 100 nF
  • Protection type: IP67: EN 60529, IP69K: ISO 20653
  • Temperature drift: < 0.1 mm/K
  • Lower signal level: 3.8 mA ... 4 mA, 0 V
  • Upper signal level : 20 mA ... 20.5 mA, 10.5 V
  • EMC: EN 61326-2-3, 2014/30/EU
  • Wetted materials: 1.4404 (Ra ? 0.8 µm), PEEK
  • Technical connections: G ѕ A
  • Housing material: 1.4305
  • Housing design: With closed lid
  • Max. probe load: ? 6 Nm
  • Temperature range during operation: –20 °C ... +60 °C
  • Temperature range during storage: –40 °C ... + 80 °C
  • Outdoor use: Only with weatherproof cover
  • Category: Fill level sensors
  • Series:LFP Inox
  • Media: liquids
  • Measurement method: limit value, continuously

Buy Sick LFP0560-G3NMB with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com offers an extensive range of industrial electrical products. We specialize in sourcing and delivering hard-to-find parts promptly. Our commitment to quality and competitive pricing makes us a preferred supplier. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet