Sick LFP2000-G1NMB
Level sensors
We ship to United States of America!
- Level monitoring in hygienic applications
- Manually cutable monoprobe up to 4,000 mm long with Ra lessthan 0.8 µm
- Process temperature up to 180 °C, process pressure up to 16 bar
Item Number:
LFP2000-G1NMB
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Specification:
Part Number | 1052085 |
Conductivity: | No limitation |
Hysteresis: | Min. 2 mm, free adjustable |
Process pressure: | -1 bar ... 16 bar |
EMC: | EN 61326-1:2006, 2004/108/EG |
Connection type: | Round connector M12 x 1, 5-pin |
Interference resistance: | EN 61000-6-2:2005 |
Protection class: | III |
Output current: | < 100 mA |
Resolution: | < 2 mm |
Temperature drift: | < 0.1 mm/K |
Probe length: | 2,000 mm |
Supply voltage: | 12 V DC ... 30 V DC |
Signal voltage LOW: | ≤ 2 V |
RoHS certificate: | + |
IO-Link: | + |
Medium: | Fluids |
Interference emission: | EN 61000-6-4:2007 |
Single- and continuous shock: | EN 60068-2-27 |
Response time: | < 400 ms |
Inductive load: | < 1 H |
Ambient temperature operation: | -20 °C ... +60 °C |
Power consumption: | ≤ 75 mA at 24 V DC without output load |
EHEDG approval: | + |
Upper signal level: | 20 mA ... 20.5 mA |
Output load: | 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V |
Housing design: | With PMMA viewing window |
MTTF: | 194.3 a (EN ISO 13849-1) |
Lower signal level: | 3.8 mA ... 4 mA |
Process connection: | G ¾ A |
UL approval: | + |
Initialization time: | ≤ 2 s |
Inactive area at process connector: | 25 mm |
Max.probe load: | 6 Nm |
Capacitive load: | 100 nF |
GOST approval: | + |
Enclosure rating: | IP 67: EN 60529, IP 69K: EN 40050 |
Process temperature: | -20 °C ... +150 °C |
Wetted parts: | 316L (Ra ≤ 0,8 µm), PEEK |
3-A: | - |
Ambient storage temperature: | -40 °C ... +80 °C |
Inactive area at probe end: | 10 mm |
Signal voltage HIGH: | Vs - 2 V |
Accuracy of sensor element: | ± 5 mm |
Dielectricity constant: | ≥ 1.8 with coaxial tube, ≥ 5 for mono probe |
Measurement: | Switch, Continuous |
Housing material: | 303 |
Repeatability: | ≤ 2 mm |
Buy Sick LFP2000-G1NMB with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com offers industrial control components. A lot of in-stock parts, contact us to check availability. If you need to receive your order as soon as possible, we can provide express delivery. We always guarantee high-quality products. Our team of experts will find the best sales prices for you. We always fulfill our obligations.
People also buy
Comments
No comments yet