Sick LMS111-10190
Level Sensor

Sick LMS111-10190
We ship to United States of America!
LMS111-10190 LASERMEASUREM.SCANNER art. 1093274
Item Number: LMS111-10190
10239.24
-
+
Total price: 10239.24
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick LMS111-10190

Datasheet:

  • Article: 1093274
  • Light source: Infrared (905 nm)
  • Laser class: 1, safe for eyes (IEC 60825-1:2014)
  • Opening angle: 190°
  • Scanning frequency: 25 Hz, 50 Hz,
  • Range: Unlimited
  • Heating: Yes
  • Working area: 0.5 m ... 10 m
  • Number of processed echoes: 2
  • Electrical connection: M12 circular connector
  • Supply voltage scanner / heater: 10.8 V ... 30 V
  • Permissible ripple frequency: ± 5%
  • Peak inrush current: 2 A
  • Scanner operating current : ? 0.4 A
  • Power consumption: 8 W, + heater 35 W (standard)
  • Casing color: Gray (RAL 7032)
  • Protection type : IP67 (according to IEC 60529)
  • Protection class: III
  • Weight: 1.1 kg, without cable
  • Dimensions: 161 mm x 102 mm x 105 mm
  • Distance from sensor to bulk material: ? 0.5 m
  • On delay: ? 60 s
  • Mean time to failure: > 100 years
  • Evaluation: 20 ms, 40 ms
  • Average filter: 0 s ... 3.600 s
  • Accuracy: ± 6%, in basic conditions and edge smoothing " high"
  • Max. belt speed: ? 20 m/s
  • Serial main interface: ?
  • Ethernet: ?
  • Auxiliary interface: ?
  • Switching inputs: 2 (+ Encoder)
  • Switching outputs: 3
  • Analog signals: Can be ordered as separate equipment BAM100
  • Communication interface: Serial master interface, 1 , RS-232 / RS-422, 115.2 kBaud, Ethernet, 1, TCP/IP, 100 Mbit/s, Auxiliary interface, 1, RS-232, 115.2 kBaud,
  • Optical indication : 5 LEDs (optional 7-segment indicator)
  • Electromagnetic compatibility (EMC): IEC 61000-6-2:2016-08 / IEC 61000-6-3:2006-07 / EN 61000-6- 2:2005 / EN 61000-6-3 / A1 2011
  • Operating temperature range: –30 °C ... +50 °C
  • Storage temperature: –40 °C . .. +70 °C
  • Insensitivity to external light sources: 40.000 lx
  • Protocol: RS-232 / RS-422
  • Baud rate: ? 115 ,2 kBaud
  • Protocol: TCP/IP
  • Data transfer rate: 100 Mbit/s
  • Protocol: RS-232
  • Speed data transmission: ? 115.2 kBaud
  • Category: Flow sensors
  • Series: Bulkscan ®

Comments

No comments yet

Write a comment