Sick LMS511-20190
Level Sensor

Sick LMS511-20190
We ship to United States of America!
LMS511-20190 LASERMEASUREM.SCANNER art. 1059529
  • Category:Flow sensors
  • Series:Bulkscan®
Item Number: LMS511-20190
20211.77
-
+
Total price: 20211.77
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick LMS511-20190

Datasheet:

  • Article: 1059529
  • Light source: Infrared (905 nm)
  • Laser class: 1, safe for eyes (IEC 60825-1:2014)
  • Opening angle: 190°
  • Scanning frequency: 35 Hz, 50 Hz, 75 Hz,
  • Range: Unlimited
  • Heating: Yes
  • Working area: 0.5 m ... 20 m
  • Number of processed echoes: 5
  • Electrical connection: M12 circular connector
  • Scanner/heater supply voltage: 19.2 V ... 28.8 V
  • Permissible ripple frequency: ± 5%
  • Peak inrush current: 2 A
  • Scanner operating current: ? 1.3 A
  • Power consumption: 22 W, + 55 W heater (standard)
  • Casing color: Gray (RAL 7032)
  • Protection type: IP67 (according to IEC 60529)
  • Protection class: III
  • Weight: 3.7 kg
  • Dimensions: 160 mm x 155 mm x 185 mm
  • Distance from sensor to bulk material: ? 0.5 m
  • On delay: ? 60 s
  • Mean time to failure: > 100 years
  • Evaluation: 13 ms, 20 ms, 28 ms
  • Average filter: 0 s ... 3.600 s
  • Accuracy: ± 3%, in basic conditions
  • Max. belt speed: ? 30 m/s
  • Auxiliary interface: ?
  • Serial main interface: ?
  • Ethernet: ?
  • Switching inputs: 2 (+ Encoder)
  • Switching outputs: 6
  • Analog signals: Can be ordered as separate equipment BAM100
  • Communication interface: Auxiliary interface, 1, USB 2.0, 500 kBaud, Serial main interface, 1, RS-232 / RS-422, 500 kBaud, Ethernet, 1, TCP/IP, 100 Mbit/s,
  • Optical indication: 5 LEDs (optional 7-segment indicator)
  • Electromagnetic compatibility (EMC): IEC 61000-6-2:2016-08 / IEC 61000-6-3:2006-07 / EN 61000-6-2:2005 / EN 61000-6-3 / A1 2011
  • Operating temperature range: –40 °C ... +60 °C
  • Storage temperature: –40 °C ... +70 ° C
  • Insensitivity to external light sources: 70,000 lx
  • Protocol: USB 2.0
  • Data transfer rate: ? 500 kBaud
  • Protocol: RS-232 / RS-422
  • Data transfer rate: ? 500 kBaud
  • Protocol: TCP/IP
  • Data transfer rate: 100 Mbit/s
  • Category:Flow sensors
  • Series:Bulkscan®

Comments

No comments yet

Write a comment