Specification:

Part Number1055376
Serial (RS-232, RS-422):+
Enclosure rating:IP 67 (EN 60529, Section 14.2.7)
Scanning frequency:25 Hz / 35 Hz / 50 Hz / 75 Hz
Operating range:0 m ... 80 m
Object remission:2 % ... > 1,000 % (reflectors)
Detectable object shape:Almost any
Electromagnetic compatibility (EMC):EN 61000-6-2:2005 / EN 61000-6-3 (2007-03)
Integrated application:Field evaluation
Statistical error :± 14 mm (20 m ... 30 m)
± 6 mm (1 m ... 10 m)
± 8 mm (10 m ... 20 m)
Protection class:III (EN 60529, Section 14.2.7)
Number of field sets:4 fields
Switching inputs:2
Response time:≥ 13 ms
PROFINET:-
Storage temperature:-30 °C ... +70 °C
Light source:Infrared (905 nm)
Variant:Lite
Data transmission rate (Ethernet):10/100 Mbit
Spot size:11.9 mrad
Data transmission rate (Serial (RS-232, RS-422)):9.6 kBaud ... 500 kBaud
Operating voltage:24 V DC± 20 %
CAN bus:-
Remark (USB):Mini-USB
Vibration resistance:EN 60068-2-6 (1995-04)
Angular resolution:0.25 °
0.5 °
1 °
Function (USB):AUX
Data transmission rate (USB):9.6 kBaud ... 500 kBaud
Function (Ethernet):Host
Fog correction:Yes
Ambient operating temperature:-30 °C ... +50 °C
Field of application:Outdoor, Security
Laser class:1 (IEC 60825-1 (2007-6)), eye-safe
Function (Serial (RS-232, RS-422)):Host
Systematic error :± 25 mm (1 m ... 10 m)
± 35 mm (10 m ... 20 m)
± 50 mm (20 m ... 30 m)
Max. range with 10 % reflectivity:40 m
Heating:Yes
Housing color:Gray (RAL 7032)
Field of view:190 °
Optical indicators:5 LEDs (additional 7-segment display)
Simultaneous processing cases:4
Ambient light safety:70,000 lx
Note on use:Not suitable for personnel protection
Electrical connection:4 x M12 circular plug-in connector
Power consumption:22 W, + 55 W heating (typical)
Switching outputs:3 (2 relay, 1 digital)
USB:+
Weight:3.7 kg
Version:Mid Range
PROFIBUS DP:-
DeviceNet:-
Resolution power:Standard Resolution
Shock resistance:EN 60068-2-27 (1993-03) / EN 60068-2-29 (1993-04)
Dimensions:160 mm x 155 mm x 185 mm
Protocol (Ethernet):TCP/IP, OPC
Ethernet:+
Amount of evaluated echoes:2

Buy Sick LMS531-11100 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com offers industrial control components. A variety of product types and sizes is available in our web catalog. All your ordered products can be sent in one delivery. We offer a price match guarantee. You can pay for multiple offers with one payment. With each day we gain more and more experience and that's why we are able to satisfy your needs for spare parts.