Sick MLG10A-0440I10501

Measuring automation light grids
Sick MLG10A-0440I10501
1799.32
One click request

Specification:

Part Number1213813
Power consumption receiver :129 mA
Response time :4.8 ms
Front screen:PMMA
Version:Pro
Output current Imax.:100 mA
Enclosure rating:IP 65, IP 67
Power consumption sender :57.25 mA
Protection class:III
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60 068-2-64)
Technology:Sender/receiver
Output load capacitive:100 nF
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Output load inductive:1 H
Maximum range :7 m
Data interface:RS-485 + 2 x I/O (IO-Link)
Initialization time:< 1 s
Detection height:440 mm
Ripple:< 5 Vpp
Weight:1.147 kg
Minimum detectable object (MDO) :10 mm
14 mm
Working range:5 m
Ambient temperature:Operation: -30 ... +55 °C, Storage: -40 ... +70 °C
Number of beams:45
Option:Nonexistent
EMC:EN 60947-5-2
Minimum range:≥0 mm
Connection type:Male connector M12, 8-pin
IO-Link:+
Indication:LED
Beam separation:10 mm
Software features:Baud rate RS-485: 9,600, Interface RS-485: beam status, Q1: presence detection, Teach-in, Standard mode
Dimensions (W x H x D):34 mm x 523.3 mm x 30.6 mm
Shock load:15 g / DIN EN 60 068-2-27 / 16 ms
Ambient light safety:Direct: 12,500 ... 150,000 lx, Indirect: ≥50,000 lx
Supply voltage Vs :DC 18 V ... 30 V
Housing material:Aluminum
Wave length:850 nm
in international format without spaces