Sick MLG5-2350F822
Item Number: MLG5-2350F822
  • Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions
  • Working range up to 8.5 m
  • Detection heights of over 3 m and up to 240 beams possible
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Specification:

Part Number1025461
Synchronization:Cable
Maximum range :12 m
Supply voltage Vs :DC 18 V ... 30 V
Front screen:PMMA
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Dimensions (W x H x D):34 mm x 2,464 mm x 29 mm
Power consumption sender :236 mA
Shock load:10 g / IEC 68-2-29 / 16 ms
Indication:7-segment display, LED
Output current Imax.:100 mA
Ambient light safety :Direct: ≥12,500 lx, Indirect: ≥50,000 lx
Wave length:IR 880 nm
Ripple:< 5 Vpp
Switching output:3 x PNP
Working range :8.5 m
Connection type:Male connector M12, 8-pin
Output load inductive:1 H
Task:Measurement light grid
Power consumption receiver :244 mA
EMC:EN 60947-5-2
Minimum detectable object (MDO) :Parallel beam: ≥60 mm
Output load capacitive:100 nF
Beam separation:50 mm
Enclosure rating:IP 65
Weight:5.905 kg
Number of beams:48
Technology:Sender/receiver
Vibration resistance:5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
Response time :Parallel beam: ≥8.2 ms
Minimum range:Parallel beam: ≥0 mm
Power consumption:236 mA
Housing material:Aluminum
Protection class:III
Inputs:1 x PNP
Ambient temperature:Operation: -25 ... +55 °C, Storage: -40 ... +70 °C
Detection height:2,350 mm
Configuration:Parameterization interface (measuring)
Initialization time:1 s

Comments

No comments yet

Write a comment

in international format without spaces