Sick MOC3ZA-KAZ33A3

Sick MOC3ZA-KAZ33A3
We ship to United States of America!
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Item Number: MOC3ZA-KAZ33A3
711.76
-
+
Total price: 711.76
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number6044982
PFHd:41 1E-09 (EN ISO 13849)
Contact configuration (safety contacts):3 contacts NO, 1 contact NC
Maximum switching frequency:1,200 /h
Voltage threshold Uan:20 mV ... 400 mV, adjustable
Measurement inputs:L1/L2/L3
Response time:100 ms
Stop category:1 (EN 60204-1)
Mounting:35 mm mounting rail according to EN 60715
Dimensions (W x H x D):45 mm x 112 mm x 121 mm
For UL 508 applications only:600 V AC
TM (mission time):20 a (EN ISO 13849)
Contact service life at 230 V / 5 A (AC) cos φ = 0.5:≥ 2 1E 05 switching operations
Supply voltage semiconductor diagnostic outputs (A3/A4):24 V DC (11 V DC ... 30 V DC)
Enclosure rating terminals:IP 20
Power consumption:6 VA
Category:Category 4 (EN ISO 13849-1)
Vibration resistance:(EN 60068-2-6)
Performance level:PL e (EN ISO 13849-1)
Standstill time ts:0.2 s ... 6 s, adjustable
Safe state in the event of a fault:The N/O is open; in other words, the safety-related enabling current paths are interrupted.
Semiconductor application diagnostics outputs (ON, ERR):Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error
Signal contacts 53/54 (normally open contact):3 A/250 V AC G. P.
Hysteresis (for detection of running motor):100 %
Climate conditions according to:25/060/04 (EN 60068-1)
Safety outputs:Normally open contact (13/14, 23/24, 33/34)
Mechanical life:≥ 50 1E 06 switching operations
Measured/motor voltage:690 V AC
Contact type:Relay, positively guided
Weight:400 g
Nominal switching voltage:250 V AC
Protection class housing:IP 40
Positively guided N/C contacts:Normally closed contact (41/42)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Switching capacity in accordance with AC 15:N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Switching capacity in accordance with DC 13:2 A/24 V DC (EN 60947-5-1)
Standstill:+

Buy Sick MOC3ZA-KAZ33A3 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers high-quality industrial control products. Our extensive inventory and prompt delivery options ensure you receive your order quickly. We prioritize quality and customer satisfaction. Contact us today to learn more about our offerings.

Comments

No comments yet

Write a comment