Sick MOC3ZA-KAZ34A3

Sick MOC3ZA-KAZ34A3
We ship to United States of America!
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Item Number: MOC3ZA-KAZ34A3
721.11
-
+
Total price: 721.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick MOC3ZA-KAZ34A3 is outdated.

Specification:

Part Number6047865
Protection class housing:IP 40
Mechanical life:≥ 50 1E 06 switching operations
Signal contacts 53/54 (normally open contact):3 A/250 V AC G. P.
Standstill time ts:0.2 s ... 6 s, adjustable
Hysteresis (for detection of running motor):100 %
Climate conditions according to:25/060/04 (EN 60068-1)
Stop category:1 (EN 60204-1)
Contact configuration (safety contacts):3 contacts NO, 1 contact NC
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Weight:400 g
Maximum switching frequency:1,200 /h
Switching capacity in accordance with DC 13:2 A/24 V DC (EN 60947-5-1)
Contact type:Relay, positively guided
Supply voltage semiconductor diagnostic outputs (A3/A4):24 V DC (11 V DC ... 30 V DC)
Measured/motor voltage:690 V AC
TM (mission time):20 a (EN ISO 13849)
Vibration resistance:(EN 60068-2-6)
Contact service life at 230 V / 5 A (AC) cos ? = 0.5:≥ 2 1E 05 switching operations
Positively guided N/C contacts:Normally closed contact (41/42)
PFHd:41 1E-09 (EN ISO 13849)
Semiconductor application diagnostics outputs (ON, ERR):Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error
Dimensions (W x H x D):45 mm x 112 mm x 121 mm
Measurement inputs:L1/L2/L3
Safety outputs:Normally open contact (13/14, 23/24, 33/34)
Performance level:PL e (EN ISO 13849-1)
Response time:100 ms
Enclosure rating terminals:IP 20
Standstill:+
Mounting:35 mm mounting rail according to EN 60715
Voltage threshold Uan:20 mV ... 400 mV, adjustable
For UL 508 applications only:600 V AC
Nominal switching voltage:250 V AC
Category:Category 4 (EN ISO 13849-1)
Switching capacity in accordance with AC 15:N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Power consumption:6 VA
Safe state in the event of a fault:The N/O is open; in other words, the safety-related enabling current paths are interrupted.

Buy Sick MOC3ZA-KAZ34A3 with the best possible price and delivery terms on eltra-trade.com

Discover a wide selection of industrial electrical products at eltra-trade.com. We specialize in sourcing and delivering the parts you need promptly. Our commitment to quality and competitive pricing sets us apart. Partner with us for reliable and efficient electrical supply solutions.

Comments

No comments yet

Write a comment