Sick MOC3ZA-KAZ34A3

Sick MOC3ZA-KAZ34A3
We ship to United States of America!
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Item Number: MOC3ZA-KAZ34A3
721.11
-
+
Total price: 721.11
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Sick MOC3ZA-KAZ34A3 is outdated.

Specification:

Part Number6047865
Protection class housing:IP 40
Mechanical life:≥ 50 1E 06 switching operations
Signal contacts 53/54 (normally open contact):3 A/250 V AC G. P.
Standstill time ts:0.2 s ... 6 s, adjustable
Hysteresis (for detection of running motor):100 %
Climate conditions according to:25/060/04 (EN 60068-1)
Stop category:1 (EN 60204-1)
Contact configuration (safety contacts):3 contacts NO, 1 contact NC
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Weight:400 g
Maximum switching frequency:1,200 /h
Switching capacity in accordance with DC 13:2 A/24 V DC (EN 60947-5-1)
Contact type:Relay, positively guided
Supply voltage semiconductor diagnostic outputs (A3/A4):24 V DC (11 V DC ... 30 V DC)
Measured/motor voltage:690 V AC
TM (mission time):20 a (EN ISO 13849)
Vibration resistance:(EN 60068-2-6)
Contact service life at 230 V / 5 A (AC) cos ? = 0.5:≥ 2 1E 05 switching operations
Positively guided N/C contacts:Normally closed contact (41/42)
PFHd:41 1E-09 (EN ISO 13849)
Semiconductor application diagnostics outputs (ON, ERR):Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error
Dimensions (W x H x D):45 mm x 112 mm x 121 mm
Measurement inputs:L1/L2/L3
Safety outputs:Normally open contact (13/14, 23/24, 33/34)
Performance level:PL e (EN ISO 13849-1)
Response time:100 ms
Enclosure rating terminals:IP 20
Standstill:+
Mounting:35 mm mounting rail according to EN 60715
Voltage threshold Uan:20 mV ... 400 mV, adjustable
For UL 508 applications only:600 V AC
Nominal switching voltage:250 V AC
Category:Category 4 (EN ISO 13849-1)
Switching capacity in accordance with AC 15:N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Power consumption:6 VA
Safe state in the event of a fault:The N/O is open; in other words, the safety-related enabling current paths are interrupted.